1-1. The meaning of the data for each address is explained below.
$4X commands
Command
CANCEL
FOCUS-ON
1 TRACK JUMP
10 TRACK JUMP
2N TRACK JUMP
N TRACK MOVE
AS3
AS2
AS1
AS0
0
0
0
0
0
1
1
1
1
0
0
RXF
1
0
1
RXF
1
1
0
RXF
1
1
1
RXF
RXF = 0 FORWARD
RXF = 1 REVERSE
When the FOCUS-ON command ($47) is canceled, $02 is sent and the auto sequence is interrupted.
When the TRACK JUMP/MOVE commands ($48 to $4F) are canceled, $25 is sent and the auto sequence is
interrupted.
$5X commands
Auto sequence timer setting
Setting timers: A, E, C, B
Command
D3
Blind (A, E), Over flow (C) 0.18ms
Brake (B)
0.36ms
D2
0.09ms
0.18ms
D1
0.05ms
0.09ms
D0
0.02ms
0.05ms
Ex.) D2 = D0 = 1, D3 = D1 = 0 (Initial reset)
A = E = C = 0.11ms
B = 0.23ms
$6X commands
Auto sequence timer setting
Setting timer: D
Command
KICK (D)
D3
D2
11.6ms 5.8ms
Ex.) D3 = 0, D2 = D1 = D0 = 1 (Initial reset)
D = 10.15ms
D1
2.9ms
D0
1.45ms
$7X commands
Auto sequence TRACK JUMP/MOVE count setting (N)
Command
Data 1
Data 2
Data 3
Data 4
D3 D2 D1 D0 D3 D2 D1 D0 D3 D2 D1 D0 D3 D2 D1 D0
Auto sequence track jump
count setting
215
214
213
212
211
210
29
28
27
26
25
24
23
22
21
20
This command is used to set N when a 2N TRACK JUMP and an N TRACK MOVE are executed for auto
sequence.
The maximum track count is 65,535, but note that with 2N track jumps the maximum track jump count is
determined by the mechanical limitations of the optical system.
The number of track jump is counted according to the signals input from CNIN pin.