First Prev 11 12 13 14 15 16 17
LC6514B
Continued from preceding page.
Mnemonic
SCTL bit
RCTL bit
WTTM
Set control register
bit (S)
Reset control
register bit (S)
Write timmer
HALT
NOP
Halt
No operation
Instuction code
D7D6D5D4
0010
1000
0010
1001
1111
D3D2D1D0
1100
B3B2B1B0
1100
B3B2B1B0
1001
1111
0110
Bytes Cycles
Function
2
2 CTL(CTL) V
B3B2B1B0
2
2 CTL(CTL)
B3B2B1B0
1
1 TM(E), (AC)
TMF0
1
1 Halt
Description
Immediate data B3B2B1B0-specified bits
in the control register are set.
Immediate data B3B2B1B0-specified bits
in the control register are reset.
The E and AC contents are loaded in the
timer. The TMF is reset.
The standby mode is entered.
Status
flag
affected
ZF
TMF
Remarks
0000
*1
0000
1
1 No operation
No operation is performed, but 1
machine cycle is consumed.
If the L1 instruction or CLA instruction is used consecutively in such a manner
as LI, LI, LI, -----, or CLA, CLA, CLA,-----, the first LI instruction or CLA
instruction only is effective and the following LI instructions or CLA instruc-
tions are changed to the NOP instructions.
Specifications of any and all SANYO products described or contained herein stipulate the performance,
characteristics, and functions of the described products in the independent state, and are not guarantees
of the performance, characteristics, and functions of the described products as mounted in the customer's
products or equipment. To verify symptoms and states that cannot be evaluated in an independent device,
the customer should always evaluate and test devices mounted in the customer's products or equipment.
SANYO Electric Co., Ltd. strives to supply high-quality high-reliability products. However, any and all
semiconductor products fail with some probability. It is possible that these probabilistic failures could
give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire,
or that could cause damage to other property. When designing equipment, adopt safety measures so
that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective
circuits and error prevention circuits for safe design, redundant design, and structural design.
In the event that any or all SANYO products(including technical data,services) described or
contained herein are controlled under any of applicable local export control laws and regulations,
such products must not be exported without obtaining the export license from the authorities
concerned in accordance with the above law.
No part of this publication may be reproduced or transmitted in any form or by any means, electronic or
mechanical, including photocopying and recording, or any information storage or retrieval system,
or otherwise, without the prior written permission of SANYO Electric Co., Ltd.
Any and all information described or contained herein are subject to change without notice due to
product/technology improvement, etc. When designing equipment, refer to the "Delivery Specification"
for the SANYO product that you intend to use.
Information (including circuit diagrams and circuit parameters) herein is for example only ; it is not
guaranteed for volume production. SANYO believes information herein is accurate and reliable, but
no guarantees are made or implied regarding its use or any infringements of intellectual property rights
or other rights of third parties.
This catalog provides information as of October, 2001. Specifications and information herein are subject
to change without notice.
PS No.180217/17