DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LRI512 Просмотр технического описания (PDF) - STMicroelectronics

Номер в каталоге
Компоненты Описание
производитель
LRI512 Datasheet PDF : 54 Pages
First Prev 31 32 33 34 35 36 37 38 39 40 Next Last
LRI512
ACTIVATE EAS
Command Code = 0xA0
When receiving the Activate EAS Request, the
LRI512 set the non-volatile EAS bit. The
Option_Flag is not supported.
During the write cycle tW, no modulation (never
100% nor 10%) shall occur. If so, the LRI512 may
not set correctly the EAS bit. The tW delay is a mul-
tiple of t1nominal.
Request parameter (Table 46):
– UID (Optional)
Response parameter (Table 47):
– No parameter.
Response parameter (Table 48):
– Error Code as Error_Flag is set
Table 46. Activate EAS Request Format
Request
SOF
Request
Flags
Activate EAS IC Mfg code
8 bits
0xA0
0x02
UID
64 bits
CRC16
16 bits
Request
EOF
Table 47. Activate EAS Response Format when Error Flag is NOT Set
Response SOF
Response_Flags
CRC16
8 bits
16 bits
Response EOF
Table 48. Activate EAS Response Format when Error Flag is Set
Response SOF Response_Flags
Error Code
CRC16
8 bits
8 bits
16 bits
Response EOF
Figure 41. ACTIVATE EAS Frame Exchange between VCD and LRI512
VCD
LRI512
LRI512
SOF Activate EAS EOF
Request
SOF
t1
Activate EAS
Response
EOF
Write sequence when error
SOF Activate EAS EOF
tw
t1
Response
AI06839
37/54

Share Link: 