DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LRI512 Просмотр технического описания (PDF) - STMicroelectronics

Номер в каталоге
Компоненты Описание
производитель
LRI512 Datasheet PDF : 54 Pages
First Prev 31 32 33 34 35 36 37 38 39 40 Next Last
LRI512
SELECT
Command Code = 0x25
When receiving the Select Command:
– if the UID is equal to its own UID, the LRI512 en-
ter or stay in the Selected state and send a Re-
sponse.
– if it is different, the selected LRI512 return to the
Ready state and do not send a Response.
Request parameter (Table 34):
– UID
Response parameter (Table 35):
– No parameter.
Response parameter (Table 36):
– Error Code as Error_Flag is set
Table 34. Select Request Format
Request
SOF
Request
Flags
Select
8 bits
0x25
UID
64 bits
CRC16
16 bits
Request
EOF
Table 35. Select Block Response Format when Error Flag is NOT Set
Response SOF
Response_Flags
CRC16
8 bits
16 bits
Response EOF
Table 36. Select Response Format when Error Flag is Set
Response SOF Response_Flags
Error Code
8 bits
8 bits
CRC16
16 bits
Response EOF
Figure 37. SELECT Frame Exchange between VCD and LRI512
VCD
LRI512
SOF Select Request EOF
SOF Select Response EOF
t1
AI06835
33/54