SYSTEM OVERVIEW
CCD
V-DRIVER
H1–H4, RG
CCDIN
V1–V4, VSG1–VSG8, SUBCK
DOUT
AD9848/AD9849
INTEGRATED
AFE+TD
DIGITAL IMAGE
PROCESSING
HD, VD
ASIC
CLI
SERIAL
INTERFACE
Figure 1a. Typical Application (Internal Mode)
AD9848/AD9849
CCD
V-DRIVER
V1–V4, VSG1–VSG8, SUBCK
H1–H4, RG
CCDIN
AD9848/AD9849
INTEGRATED
AFE+TD
DOUT
CLPOB
CLPDM
PBLK
HBLK
HD, VD
DIGITAL IMAGE
PROCESSING
ASIC
CLI
SERIAL
INTERFACE
Figure 1b. Typical Application (External Mode)
Figures 1a and 1b show the typical system application diagrams
for the AD9848/AD9849. The CCD output is processed by the
AD9848/AD9849’s AFE circuitry, which consists of a CDS,
PxGA, VGA, black level clamp, and A/D converter. The
digitized pixel information is sent to the digital image
processor chip, where all post-processing and compression
occurs. To operate the CCD, CCD timing parameters are
programmed into the AD9848/AD9849 from the image
processor, through the 3-wire serial interface. From the system
master clock, CLI, provided by the image processor, the
AD9848/AD9849 generates the high speed CCD clocks and all
internal AFE clocks. All AD9848/AD9849 clocks are
synchronized with VD and HD.
Figure 1a shows the AD9848/AD9849 used in Internal Mode, in
which all the horizontal pulses (CLPOB, CLPDM, PBLK,
and HBLK) are programmed and generated internally. Figure 1b
shows the AD9848/AD9849 operating in External Mode, in
which the horizontal pulses are supplied externally by the
image processor.
The H-drivers for H1–H4 and RG are included in the AD9848/
AD9849, allowing these clocks to be directly connected to the
CCD. H-drive voltage of 5 V is supported in the AD9849.
Figure 2 shows the horizontal and vertical counter dimensions
for the AD9848/AD9849. All internal horizontal clocking is
programmed using these dimensions to specify line and
pixel locations.
MAXIMUM FIELD DIMENSIONS
12-BIT HORIZONTAL = 4096 PIXELS MAX
12-BIT VERTICAL = 4096 LINES MAX
Figure 2. Vertical and Horizontal Counters