Philips Semiconductors
10 and 1 page intelligent teletext decoders
Preliminary specification
SAA5264; SAA5265
EMC GUIDELINES
Optimization of circuit return paths and minimization of
common mode emission will be assisted by using a double
sided Printed Circuit Board (PCB) with low inductance
ground plane.
On a single-sided PCB a local ground plane under the
whole IC should be present as shown in Fig.3. This should
have the widest possible connection between the PCB
ground and bulk electrolytic decoupling capacitor.
Preferably, the PCB local ground plane connection should
not be connected to other grounds on route to the PCB
ground. Do not use wire links. Wire links cause ground
inductance which increases ground bounce.
The supply pins can be decoupled at the ground pin plane
below the IC. This is easily achieved by using surface
mount capacitors, which, at high frequency, are more
effective than components with leads.
Using a device socket would increase the area and
therefore increase the inductance of the external bypass
loop.
To provide a high-impedance to any high frequency
signals on the VDD supplies to the IC, a ferrite bead or
inductor can be connected in series with the supply line
close to the decoupling capacitor. To prevent signal
radiation, pull-up resistors of signal outputs should not be
connected to the VDD supply on the IC side of the ferrite
bead or inductor.
OSCGND should only be connected to the crystal load
capacitors and not to any other ground connection.
Distances to physical connections of associated active
devices should be as short as possible.
PCB output tracks should have close proximity, mutually
coupled, ground return paths.
handbook, full pagewidth
other
GND
connections
under-IC GND plane
GND connection
note: no wire links
GND +3.3 V
electrolytic decoupling capacitor (2 µF)
ferrite beads
SM decoupling capacitors (10 to 100 nF)
under-IC GND plane
VSSC
VSSA
IC
MBK979
2000 Jan 27
Fig.3 Power supply connections for EMC.