DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX3544 Просмотр технического описания (PDF) - Maxim Integrated

Номер в каталоге
Компоненты Описание
производитель
MAX3544
MaximIC
Maxim Integrated MaximIC
MAX3544 Datasheet PDF : 20 Pages
First Prev 11 12 13 14 15 16 17 18 19 20
Multiband Digital Television Tuner
Table 14. R0A: VAS CONFIG Register—VCO Autoselect Configuration (Address: 0Ah)
BIT NAME
BIT LOCATION
(0 = LSB)
LFDIV[1:0]
7:6
TYPICAL
SETTING
00
FUNCTION
Sets the low-frequency clock-divider.
00 = Use for 16MHz ≤ fREF < 20MHz
01 = Use for 20MHz ≤ fREF < 28MHz
10 = Use for 28MHz ≤ fREF ≤ 32MHz
11 = Unused
VASS
5
VAS
4
Controls the VCO autoselect (VAS) start conditions function.
0
0 = VAS starts from the current VCO/VCOSB loaded in the VCO[1:0] and VSUB[3:0]
bits (in R00)
1 = VAS starts from the currently used VCO and VCOSB
1
Controls the VCO autoselect (VAS) function. Must set to 1 for proper operation.
ADL
3
Enables or disables the VCO tuning voltage ADC latch when the VCO autoselect
0
(VAS) mode is disabled.
0 = Disables the ADC latch
1 = Latches the ADC value
ADE
2
Enables or disables VCO tuning voltage ADC read when the VCO autoselect (VAS)
0
mode is disabled.
0 = Disables ADC read
1 = Enables ADC read
LTC[1:0]
1:0
10
Sets the VCO autoselect wait time. Must set to 10 for proper operation.
Note: Only production tested and guaranteed functional in states 0001 0010, 0101 0010, and 1001 0010. All other states are
untested and may not function correctly. Contact Maxim if untested settings will be used in production.
Table 15. R0B: PWRDET CFG1 Register—Power-Detector Configuration 1 of 2 (Address: 0Bh)
BIT NAME
BIT LOCATION
(0 = LSB)
DWPD
7
WPDA[2:0]
6:4
DNPD
3
NPDA[2:0]
2:0
TYPICAL
SETTING
0
100
0
011
FUNCTION
Enables or disables wideband power detector. Use this state for autonomous
RFAGC.
0 = Enables wideband power detector
1 = Disables wideband power detector
Sets the wideband power-detector attack point (takeover point).
000 = Min
100 = Nom (see the Typical Operating Characteristics)
111 = Max
Enables or disables narrowband power detector. Use this state for autonomous
RFAGC.
0 = Enables narrowband detector
1 = Disables narrowband detector
Sets the narrowband power-detector attack point (takeover point).
000 = Min
011 = Nom (see the Typical Operating Characteristics)
111 = Max
Note: Only production tested and guaranteed functional in state X100 X011, where X can be either 0 or 1. All other states are
untested and may not function correctly. Contact Maxim if untested settings will be used in production.
14   �������������������������������������������������������������������������������������

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]