DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LC89971M Просмотр технического описания (PDF) - SANYO -> Panasonic

Номер в каталоге
Компоненты Описание
производитель
LC89971M
SANYO
SANYO -> Panasonic SANYO
LC89971M Datasheet PDF : 9 Pages
1 2 3 4 5 6 7 8 9
LC89971, 89971M
4. Measure the comb depth from the C-OUT output with a 350 mVp-p sine wave signal of frequency fa input to C-IN1
and C-IN2 and with a frequency of fb input.
CD
=
20
log
C-OUT
C-OUT
output
output
with
with
fb
fa
input
input
[mVp-p]
[mVp-p]
[dB]
Test frequencies
fa
CD-1 4.431395 MHz
CD-2 3.571628 MHz
CD-3 3.571628 MHz
fb
4.435303 MHz (PAL/GBI)
3.575561 MHz (PAL/M)
3.575561 MHz (NTSC/M)
5. Measure the C-OUT output with a 200 mVp-p sine wave signal input to C-IN1 and C-IN2 and with 500 mVp-p sine
wave signal input and calculate the difference in the gains.
LNC = 20 log
Output for a 500 mVp-p input [mVp-p]
500 [mVp-p]
Output for a 200 mVp-p input [mVp-p]
200 [mVp-p]
[dB]
Test frequencies
LNC-1 4.431395 MHz (PAL/GBI)
LNC-2 3.571628 MHz (PAL/M)
LNC-3 3.571628 MHz (NTSC/M)
6. Measure the 4 fsc (14.3 MHz) and fsc (3.58 MHz) components in the C-OUT output with no input.
7. Measure the noise in the C-OUT output with no input.
Measure the noise with a noise meter set up with a 200 kHz high-pass filter and a 5 MHz low-pass filter.
8. Let V1 be the C-OUT output with a 350 mVp-p sine wave input to C-IN1 and C-IN2 and SW3 set to a, and let V2 be
the C-OUT output with SW3 set to b.
ZOC
=
V2
[mVp-p] – V1 [mVp-p]
V1 [mVp-p]
×
500
[]
Test frequencies
ZOC-1 4.431395 MHz (PAL/GBI)
ZOC-2 3.571628 MHz (PAL/M)
ZOC-3 3.571628 MHz (NTSC/M)
9. The C-OUT output delay time with respect to inputs to C-IN1. (the CCD 2.5 bit delay)
10. Y-OUT voltage (clamp voltage) with no signal input.
11. Measure the Y-OUT output with a 200 kHz 400 mVp-p sine wave input to Y-IN.
GVY
=
20
log
Y-OUT output [mVp-p]
400 [mVp-p]
[dB]
12. Measure the Y-OUT output with a 200 kHz 200 mVp-p sine wave input to Y-IN and with a 3.3 MHz 200 mVp-p
sine wave input.
GFY = 20 log
Y-OUT output with a 3.5 MHz input [mVp-p]
Y-OUT output with a 200 kHz input [mVp-p]
[dB]
Note that Vbias should be adjusted so that the circuit is biased to the clamp level plus 250 mV.