A8425
High Current Photoflash Capacitor Charger
with IGBT Driver for Two Li+ Batteries
Common Parameters
Symbol Parameter Units/Division
C1
VOUT
50 V
C2
VBAT
2V
C3
IIN
250 mA
t
time
500 ms
Conditions Parameter
Value
VIN
3.6 V
VBAT
3.6 V
COUT
100 μF/330 V
Transformer = DCT9.5/5ER, LP = 7 μH, N = 10
Performance Characteristics
Charging Time at Various Peak Current Levels
Conditions Parameter
Value
C1
RSET
25 kΩ
C2
IP
≈3.15 A
C3
tCHARGE= 1.77 s
t
VOUT
C1
VBAT
C2
IIN
C3
VOUT
C1
Conditions Parameter
Value
C1
RSET
30 kΩ
C2
IP
≈2.6 A
C3
tCHARGE= 2.17 s
t
VBAT
C2
IIN
C3
VOUT
C1
Conditions Parameter
Value
C1
RSET
IP
45 kΩ
≈1.8 A
C2
C3
tCHARGE= 3.58 s
t
VBAT
C2
IIN
C3
Allegro MicroSystems, Inc.
7
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com