IS61LPS25632T/D/J, IS61LPS25636T/D/J, IS61LPS51218T/D/J
SNOOZE MODE ELECTRICAL CHARACTERISTICS
Symbol Parameter
ISB2
Current during SNOOZE MODE
tPUS
ZZ inactive to input sampled
tZZI
ZZ active to SNOOZE current
tRZZI
ZZ inactive to exit SNOOZE current
Conditions
ZZ ≥ Vih, Com.
ZZ ≥ Vih, Ind.
Min.
—
—
2
—
0
®
ISSI
Max.
30
40
—
2
—
Unit
mA
cycle
cycle
ns
SNOOZE MODE TIMING
CLK
ZZ
Isupply
tPDS
ZZ setup cycle
tZZI
ISB2
All Inputs
(except ZZ)
Deselect or Read Only
Outputs
(Q)
High-Z
tPUS
ZZ recovery cycle
tRZZI
Deselect or Read Only
Normal
operation
cycle
Don't Care
Integrated Silicon Solution, Inc. — www.issi.com — 1-800-379-4774
19
PRELIMINARYINFORMATION Rev. 00B
04/29/02