CPM2C-S10C
CPM2C-S10C
s General and Performance Specifications (continued)
Item
Data Memory
Read/Write
Basic interrupt functions
High-speed counter
functions
Quick-response inputs
Read-only
PC Setup
Input interrupts
Scheduled
interrupts
High-speed
counter
Counter interrupt
Input interrupts
(counter mode)
Count-up interrupt
Pulse outputs
Synchronized pulse control
Input time constant
(ON response time = OFF response time)
Clock function
Communications
functions
Peripheral port:
RS-232C port:
Memory protection
Memory backup
Self-diagnostic functions
Program checks
Connection tools
Programming
console
SSS
CPT
CX-P
Specifications
2,048 words (DM 0000 to DM 2047)
The Error Log is contained in DM 2000 to DM 2021
456 words (DM 6144 to DM 6599)
56 words (DM 6600 to DM 6655)
2 interrupts (shared by input interrupt counter mode and the quick-response inputs)
1 interrupt
1 counter (20 kHz single-phase or 5 kHz two-phase)
1 interrupt
2 interrupts (shared by input interrupt counter mode and the quick-response inputs)
2 interrupts (shared by input interrupt counter mode and the quick-response inputs)
2 inputs
Minimum pulse input: 50 µs
Shared by input interrupts and input interrupt counter mode
Either 2 points with no acceleration/deceleration, 10 Hz to 10 kHz each, and no
direction control, 1 point with trapezoid acceleration/deceleration, 10 Hz to 10 kHz,
and direction control, or 2 points with variable duty-ratio outputs
1 point
Can be set for CPU Unit inputs and Expansion Unit input points
(1, 2, 3, 5, 10, 20, 40, or 80 ms)
Built-in RTC
Supports Host Link, peripheral bus, no protocol, or Programming Console connections
Supports Host Link, no protocol, 1:1 Slave Unit Link, 1:1 Master Unit Link,
or 1:1 NT Link connections
HR area, AR area, counter values, read/write DM area contents, and counter values
maintained during power interruptions
Non-volatile memory, user programs, read-only DM area and PC setup are backed up
Lithium battery (2-year)
DM area, HR area, AR area and counter values are backed up
CPU Unit failure (watchdog timer), memory failure, communications error, setting error,
battery error, and I/O bus error
No END instruction, programming errors (checked when operation is started)
C200H-PRO27, CQM1-PRO01, CQM1H-PRO01
IBM PC/AT or compatible (SYSMAC Support Software V1.1)
Windows
Windows
For more information, contact an Omron representative at 1-800-55-OMRON