Preliminary Information
AC Electrical Characteristics
Characteristics
Sym
1 Return Loss at junctorx
(Ref. = 604)
2 Impedance at Junctor
3 Transhybrid Lossy
(Junctor - 754)
4 Transhybrid Loss z
(Frequency = 1kHz)
5 Transhybrid Loss
(Frequency = 50kHz)
6 Input Impedance at RX
7 Output Impedance at TX
8 Gain RX to Junctor
ARJ
9 Frequency Response Gain
(relative to gain at 1kHz)
Min Typ* Max Units
Test Conditions
46
40
604
42
36
18
21
15
18
dB 200-3400Hz
dB 200-50kHz
dB 200-3400Hz
dB 200-50kHz
dB Junctor = 600
dB Junctor = 900
dB Junctor = 600
dB Junctor = 900
10k
5
0.99 1.00 1.01
-0.1 0.0 0.1
-0.1
0.1
-0.1
1.0
V/V Input 0.5V 1kHz
dBV
dB 200-3400Hz
dB 200-50kHz
10 Gain junctor to TX
AJT 0.99 1.00 1.01 V/V Input 0.5V 1kHz
-0.1
0
0.1 dBV
11 Frequency Response Gain
relative to gain at 1kHz
-0.1
0.1
dB 200-3400Hz
-0.1
0.1
dB 200Hz-50kHz
12 Signal Output Overload Level
at TX
6.0
at Junctor
6.0
dBm
dBm
%THD<5%
Reference: 600
Reference: 754
13 Total Harmonic Distortion
RX to Junctor
Junctor to TX
RX to Junctor
Junctor to TX
THD
Input 0.5V 1kHz
0.4
% 200-3400Hz
0.4
% 200-3400Hz
1.0
% 200-50kHz
1.0
% 200-50kHz
14 Idle Channel Noise
Nc
at TX
at Junctor
2 dBrnC Reference: 600
2 dBrnC Reference 754
15 Power Supply Rejection Ratio PSRR
Ripple 0.1V 1kHz
at TX and Junctor
VDD
40
dB
VEE
40
dB
* Typical figure are at 25°C with nominal +5V supplies and are for design aid only.
‡ AC Electrical Characteristics are over recommended operating conditions unless otherwise stated.
Both of the 2-4 Wire circuits are tested. TX, RX and Junctor actually refer to TX1, RX1 and JUN1; and TX2, RX2 and JUN2.
All of the above test conditions use 754connected between Junctor and AGND, unless otherwise stated.