3 / // / 50 Hz 1000 kVA
STANDARD FEATURES
// The engine-generator set complies to G3
// Engine generator set tested according to ISO 8528-5 for
transient response
// Accepts rated load in one step as per NFPA 110
// All engine-generator sets are type and factory tested
// MTU Onsite Energy is a single source supplier
// Global product support
// Cooling System (integral set-mounted; engine driven fan)
// 16V2000 diesel engine (31,84 Liter (1943 cu inch)
displacement; 4-stroke)
// Engine-generator resiliently mounted
// Complete range of accessories
// Brushless, rotating field generator (PMG excitation;
250% short circuit capability; 2/3 pitch stator windings)
// Complete system metering
// LCD display
APPLICATION DATA
// Engine
Manufacturer
Model
Type
Arrangement
Displacement/cylinder: l (cu inch)
Bore: mm (inch)
Stroke: mm (inch)
Compression ratio
Rated speed rpm
Engine governor
Max power: kWm (bhp)
Speed regulation
Air filter
// Lube Oil Capacity
MTU
16V2000G25TD
4-Stroke
16-V
1.99 (121)
130 (5.1)
150 (5.9)
16:1
1500
Electronic isochronous
890 (1194)
±0.25%
Dry
// Fuel Consumption
At 100% of power rating:
At 75% of power rating:
At 50% of power rating:
gal/hr
56
42
28
// Cooling/Radiator System
Ambient capacity of radiator: °C
Max. restriction of cooling air, intake,
and discharge side of rad.: kPa (in. H 0)
2
Water pump capacity: l/min (gpm)
Heat rejection to coolant: kW (BTUM)
Heat rejection to after cooler: kW (BTUM)
Heat radiated to ambient: kW (BTUM)
Engine coolant capacity: l (gal)
Coolant to cooler temperature: °C (°F)
Total oil system: l (gal)
102 (27) // Air Requirements
// Electrical
Electric Volts DC
Cold cranking amps under -17.8 °C (0 °F)
24
1000
// Fuel System
Fuel supply connection size
Fuel return connection size
Maximum fuel lift: m (ft)
Recommended fuel
Total Fuel Flow: L/hr (gal/hr)
M22x1,5 - 60°/Male
M12x1,5 - 60°/Male
5 (16)
see MTU fluids & lubrication spec.
600 (159)
Aspirating: m3/min (SCFM)
Air flow required for rad.
cooled unit: m3/min
// Exhaust System
Gas temp. (stack): °C (°F)
Gas volume flow
temp: m3/min (SCFM)
Maximum allowable
back pressure: kPA
l/hr
g/kwh
212
198
158
196
108
201
40 (optional 50)
0,2 (0,803)
667 (176)
400 (22,748)
170 (9,668)
45 (2559)
110 (29)
95 (203)
66 (2329)
1236 (43606)
530 (986)
180 (6350)
8,5 (34)
Represents standard product only.Consult Factory/MTU Onsite Energy distributor for additional configurations.
Values in accordance with ISO 3046-1. Conversion calculated with fuel density of 0.83 g/ml.
System ratings at 50°C may differ.
Air density = 1.184 kg/m3 (0.0739 lbm/ft3)