VKP60xTC
SPECIFICATIONS, ALL MODELS
Specifications are at T = +40°C nominal input voltage unless otherwise specified.
CASE
60 Watt Triple Output
Half Brick DC/DC Converter
PARAMETER
Output Power
Set Point Voltage
Output Current, I
OUT
Output Ripple, p-p
Output Adjust Range
Output Temperature Drift
Line Regulation
Load Regulation
Current Limit Inception
Short-Circuit Current
Transient Response
Peak Deviation
Settling Time
Overvoltage Limit
Efficiency
CONDITIONS
Total Combind O/P Power =
60 Watts Max
I
O Nom
DC to 20MHz*
*
V
IN,
Min<VIN
>VIN,
Max
I =I
O O, Nom
Min Load to Rated Load
Other Outputs Min Load
50 to 100% Load Step
V , 1% of V
OUT
OUT, Nom
IOUT1=6A, (IOUT2+IOUT3)=2.5A
F.L. V =Nomina
IN
V1
V2
Min Nom Max Min Nom Max
V3
UNITS
Min Nom Max
30
60
15
30
15
30
W
5.1
12
12
V
0.5
6.0
12
0
1.25
2.5
0
1.25 2.5
A
125 200
150
250
150 250
mV
4.75
5.50
Dependent on V1
V
.02
.05
.02
.05
.02
.05
%/°C
0.05 0.10
0.50 1.0
16
12.6 16
1.0
2.0
See Regulation Curves
5.0
4.0
5.0
1.0
2.0
%
See Regulation Curves
%
5.0
A
4.0
5.0
A
200 300
mV
35
50
μSec
6.0
6.8
V
86
87
%
PARAMETER
CONDITIONS
Output Power
Set Point Voltage
Output Current, IOUT
Output Ripple, p-p
Output Temperature Drift
Line Regulation
Load Regulation
Current Limit Inception
Short-Circuit Current
Transient Response
Peak Deviation
Settling Time
Overvoltage Limit
Efficiency
Total Combined O/P Power =
60 Watts Max
I
O Nom
DC to 20MHz*
Output Adjust Range
V
IN,
Min<VIN
>VIN,
Max
I =I
O O, Nom
Min Load to Rated Load
Other Outputs Min Load
50 to 100% Load Step
V , 1% of V
OUT
OUT, Nom
I =6A, (I +I )=2A
OUT1
OUT2 OUT3
F.L. V =Nominal
IN
* See Application Notes available on the web at www.murata-ps.com
** X = Either L (24) or M (48)
V1
V2
Min Nom Max Min Nom Max
V3
Min Nom Max
UNITS
30
60
15
30
15
30
W
5.0
15.3
15.3
V
0.5
6
12
0
1
2
0
1
2
A
100 200
125
250
125 250
mV
*
4.60
5.50
Dependent on V1
V
.02
.05
.02
.05
.02
.05
%/°C
0.05 0.10
1.0
2.0
1.0
2.0
%
0.50 1.0
See Regulation Curves
See Regulation Curves
%
16
4.0
4.0
A
12.6 16
3.2
4.0
3.2
4.0
A
200 300
mV
35
50
μSec
6.0
6.8
V
86
87
%
Device Family
Indicates 100 Watt Regulated Unit
Model Number
Selected from Table of Electrical Characteristics
Where:
x = Input Voltage (L = 24VDC, M = 48VDC)
T = Number of Outputs (Triple ‘T’)
y = 3 for 3.3V, 5 for 5V
z = 12 for 12V, 15 for 15V
Lead Length
0.250" - No Number
0.145" - (6)
0.110" - (8)
RoHS Compliant
VKp60 xTyz- L
C
www.murata-ps.com
Technical inquiries - email: sales@murata-ps.com, tel: 508 339 3000
TDC_VKP60xTC.B01 Page 4 of 7

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]