DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

VKP60LT312C Просмотр технического описания (PDF) - Murata Power Solutions

Номер в каталоге
Компоненты Описание
производитель
VKP60LT312C
Murata-ps
Murata Power Solutions Murata-ps
VKP60LT312C Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
SPECIFICATIONS, ALL MODELS
Specifications are at T = +40°C nominal input voltage unless otherwise specified.
CASE
PARAMETER
TEMPERATURE
Operation/Specification
Storage
Shutdown
Thermal Impedance
CONDITIONS
MIN
Case temperature
-40
-50
+100
Case to Ambient
VKP60xTC
60 Watt Triple Output
Half Brick DC/DC Converter
TYP
MAX
UNITS
+100
˚C
+125
˚C
+115
˚C
8.2
˚C/W
PARAMETER
Output Power
Set Point Voltage
Output Current, I
OUT
Output Ripple, p-p
Output Adjust Range
Output Temperature Drift
Line Regulation
Load Regulation
Current Limit Inception
Short-Circuit Current
Transient Response
Peak Deviation
Settling Time
Overvoltage Limit
Efficiency
CONDITIONS
Total Combined O/P Power =
60 Watts Max.
I
O Nom
DC to 20MHz*
*
V
IN,
Min<VIN
>VIN,
Max
I =I
O O, Nom
Min Load to Rated Load
Other Outputs Min Load
50 to 100% Load Step
V , 1% of V ,
OUT
OUT Nom
I =9A, (I +I )=2.5A
OUT1
OUT2 OUT3
F.L. V =Nominal
IN
V1
V2
Min Nom Max Min Nom Max
V3
UNITS
Min Nom Max
30
60
15
30
15
30
W
3.3
12.2
12.2
V
0.5
9
18
0
1.25
2.5
0
1.25 2.5
A
100 200
150
250
150 250
mV
3.15
3.80
Dependent on V1
V
.02
.05
.02
.05
.02
.05
%/°C
0.05 1.0
1.0
2.0
1.0
2.0
%
0.50 1.0
See Regulation Curves
See Regulation Curves
%
23
5.0
5.0
A
19
25
4.0
5.0
4.0
5.0
A
150 250
mV
35
50
μSec
4.2
5.0
V
85
86
%
PARAMETER
CONDITIONS
Output Power
Set Point Voltage
Output Current, I
OUT
Output Ripple, p-p
Output Adjust Range
Output Temperature Drift
Line Regulation
Load Regulation
Current Limit Inception
Short-Circuit Current
Transient Response
Peak Deviation
Settling Time
Overvoltage Limit
Efficiency
Total Combined O/P Power =
60 Watts Max.
I
O Nom
DC to 20MHz*
See Application Notes*
V
IN,
Min<VIN>VIN,
Max
I =I
O O, Nom
Min Load to Rated Load
Other Outputs Min Load
50 to 100% Load Step
VOUT, 1% of VOUT, Nom
I =9A, (I +I )=2A
OUT1
OUT2 OUT3
F.L. V =Nominal
IN
* See Application Notes available on the web at www.murata-ps.com
** X = Either L (24) or M (48)
www.murata-ps.com
V1
V2
Min Nom Max Min Nom Max
V3
UNITS
Min Nom Max
30
60
15
30
15
30
W
3.3
15.85
15.85
V
0.5
9
18
0
1
2
0
1
2
A
100 200
125
250
125 250
mV
3.15
3.80
Dependent on V1
V
.02
.05
.02
.05
.02
.05
%/°C
0.05 1.0
1.0
2.0
1.0
2.0
%
0.50 1.0
See Regulation Curves
See Regulation Curves
%
23
4.0
4.0
A
19
25
3.2
4.0
3.2
4.0
A
150 250
mV
35
50
μSec
4.2
5.0
V
85
86
%
Technical inquiries - email: sales@murata-ps.com, tel: 508 339 3000