DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

20IMX4-03-8 Просмотр технического описания (PDF) - Bel Fuse Inc.

Номер в каталоге
Компоненты Описание
производитель
20IMX4-03-8
BEL
Bel Fuse Inc. BEL
20IMX4-03-8 Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
IMX4 Series Data Sheet
4 Watt DC-DC Converters
Immunity to Environmental Conditions
Table 9: Mechanical and climatic stress
Test Method
Standard
Ca Damp heat
steady state
IEC/EN 60068-2-78
MIL-STD-810D section 507.2
Ea Shock
(half-sinusoidal)
IEC/EN 60068-2-27 1
MIL-STD-810D section 516.3
Eb Bump
(half-sinusoidal)
IEC/EN 60068-2-29
MIL-STD-810D section 516.3
Fc Vibration
(sinusoidal)
IEC/EN 60068-2-6
Fh Vibration,
broad-band
random
(digital control)
IEC/EN 60068-2-64
Kb Salt mist, cyclic
IEC/EN 60068-2-52
(sodium chloride
NaCl solution)
Test conditions
Temperature:
Relative humidity:
Duration:
40 ±2 °C
93 +2/-3 %
56 days
Acceleration amplitude:
Bump duration:
Number of bumps:
100 gn = 981 m/s2
6 ms
18 (3 each direction)
Acceleration amplitude:
Bump duration:
Number of bumps:
40 gn = 392 m/s2
6 ms
6000 (1000 each direction)
Acceleration amplitude:
Frequency (1 Oct/min):
Test duration:
0.35 mm (10 to 60 Hz)
5 gn = 49 m/s2 (60 to 2000 Hz)
10 to 2000 Hz
7.5 h (2.5 h each axis)
Acceleration spectral density:
Frequency band:
Acceleration magnitude:
Test duration:
0.05 g n2/Hz
10 to 500 Hz
4.9 gn rms
3 h (1 h each axis)
Concentration:
Duration:
Storage:
Cycles and storage duration:
5% (30 °C)
2 h per cycle
40 °C, 93% rel. humidity
3 days, 22 h per cycle
1 Covers also EN 50155/EN 61373 category 1, class B, body mounted (= chassis of coach)
Status
Converter
not
operating
Converter
operating
Converter
operating
Converter
operating
Converter
operating
Converter
not
operating
Temperatures
Table 10: Temperature specifications, valid for air pressure of 800 to 1200 hPa (800 to 1200 mbar)
Temperature
Standard (-8)
Unit
Characteristics
Conditions
min
max
TA Ambient temperature Operational 1
–40
85
°C
TC Case temperature
–40
105
TS Storage temperature
Non operational
–55
105
1 See Thermal Considerations
Failure Rates
Table 11: MTBF
MTBF
40IMX4-05-8 (MIL-HDBK-217F)
40IMX4-1212-8 (Bellcore)
Ground benign
TC = 40 °C
890 000
3 535 000
Ground fixed
Ground mobile
Unit
TC = 40 °C
TC = 70 °C
TC = 50 °C
440 000
247 000
362 000
h
1 768 000
917 000
476 000
BCD20006-G Rev AE, 16-Sep-2015
MELCHER
The Power Partners.
Page 10 of 12

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]