AP1695EV4 User Guide
120VAC Triac Dimmable GU10 LED Driver
with Integrated MOSEFT
DIODES TAPPED TRANSFORMER DESIGN
AP1695 120VAC Buck tapped 12V 400mA Transformer Spec
1) Bobbin
EEP10 4+4 pin
1
WD2: Primary
26#*1, 42Ts
6
6
WD1: P r i m a r y
21#*1, 82Ts
2
WD3: Auxiliary 13#1, 70Ts
7
5
2) Transformer Parameters
1. Primary Inductance (Pin1‐Pin7, all other windings are open)
Lp = 0.6mH ±6%@10kHz
2. Primary Winding Turns: NP=82Ts(Pin7‐Pin6) +42Ts(Pin6toPin1)
3. Auxiliary Winding Turns (Pin2‐ Pin5): NA= 70Ts (Pin 2 to Pin 5)
3) Transformer Winding Construction Diagram
Winding
Number
1
2
3
4
Windings
WD1‐Primary
Winding
WD2‐Primary
Winding
Insulation
WD3‐Auxiliary
Winding
Insulation
Winding
Specification
Start at Pin 7, wind 82 turns of single Φ0.21mm wire and finish on
Pin 6.
Start at Pin 6, wind 42 turns of single Φ0.26mm wire and finish on
Pin 1.
2 Layers of insulation tape
Start at Pin 2, wind 70 turns of single Φ0.13mm wire and finish on
Pin 5.
2 Layers of insulation tape
AP1695EV4 Rev1