Philips Semiconductors
CATV amplifier module
Product specification
BGY82
CHARACTERISTICS
Bandwidth 40 to 450 MHz; Tmb = 30 °C; ZS = ZL = 75 Ω.
SYMBOL
PARAMETER
CONDITIONS
Gp
power gain
f = 50 MHz
f = 450 MHz
SL
slope cable equivalent
f = 40 to 450 MHz
FL
flatness of frequency response f = 40 to 450 MHz
S11
input return losses
f = 40 to 80 MHz
f = 80 to 160 MHz
f = 160 to 450 MHz
S22
output return losses
f = 40 to 80 MHz
f = 80 to 160 MHz
f = 160 to 450 MHz
CTB
composite triple beat
60 channels flat; Vo = 46 dBmV;
measured at 445.25 MHz
Xmod
cross modulation
60 channels flat; Vo = 46 dBmV;
measured at 55.25 MHz
CSO
composite second order
distortion
60 channels flat; Vo = 46 dBmV;
measured at 446.25 MHz
d2
second order distortion
note 1
Vo
output voltage
dim = −60 dB; note 2
F
noise figure
f = 450 MHz
Itot
total current consumption (DC) note 3
MIN.
13.5
14.5
0.2
−
20
19
18
20
19
18
−
−
−
−
61.5
−
−
TYP.
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
180
MAX.
14.5
−
1.5
±0.2
−
−
−
−
−
−
−55
−56
−55
−72
−
7
200
UNIT
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dBmV
dB
mA
Notes
1. fp = 55.25 MHz; Vp = 46 dBmV;
fq = 391.25 MHz; Vq = 46 dBmV;
measured at fp + fq = 446.5 MHz.
2. Measured according to DIN45004B:
fp = 440.25 MHz; Vp = Vo;
fq = 447.25 MHz; Vq = Vo −6 dB;
fr = 449.25 MHz; Vr = Vo −6 dB;
measured at fp + fq − fr = 438.25 MHz.
3. The module normally operates at VB = 24 V, but is able to withstand supply transients up to 30 V.
1998 Mar 02