PCB motion due to button
presses must be minimized to
maintain optical alignment.
9. Install mouse top case. There
must be a feature in the top
case to press down onto the
clip to ensure all components
are interlocked to the correct
vertical height.
R_BIN
LED
XY_LED
LED
DRIVE
REFA
REFB
VOLTAGE
REFERENCE
Figure 6. Block diagram of ADNS-2030 optical mouse sensor.
PCB Assembly Considerations
1. Insert the sensor and all other
electrical components into
PCB.
2. Bend the LED leads 90° and
then insert the LED into the
assembly clip until the snap
feature locks the LED base.
3. Insert the LED/clip assembly
into PCB.
4. Wave Solder the entire
assembly in a no-wash solder
process utilizing solder
fixture. The solder fixture is
needed to protect the sensor
during the solder process. The
fixture should be designed to
expose the sensor leads to
solder while shielding the
optical aperture from direct
solder contact. The solder
fixture is also used to set the
reference height of the sensor
to the PCB top during wave
soldering (Note: DO NOT
remove the kapton tape during
wave soldering).
5. Place the lens onto the base
plate.
6. Remove the protective kapton
tape from optical aperture of
the sensor. Care must be taken
to keep contaminants from
entering the aperture. It is
recommended not to place the
PCB facing up during the
entire mouse assembly pro-
cess. The PCB should be held
vertically during the kapton
removal process.
7. Insert PCB assembly over the
lens onto the base plate
aligning post. The sensor
aperture ring should self-align
to the lens.
8. The optical position reference
for the PCB is set by the base
plate and lens. Note that the
Design Considerations for Improving
ESD Performance
The flange on the lens has been
designed to increase the creepage
and clearance distance for
electrostatic discharge. The table
below shows typical values
assuming base plate construction
per the Agilent supplied IGES file
and HDNS-2100 lens flange.
Typical Distance
Creepage
Clearance
Millimeters
16.0
2.1
For improved ESD performance,
the lens flange can be sealed (i.e.
glued) to the base plate. Note
that the lens material is polycar-
bonate and therefore, cyanoacry-
late based adhesives or other
adhesives that may damage the
lens should NOT be used.
Sensor
Clip
PCB
Lens/Light Pipe
Base Plate
LED
N
c
o
Surface
Figure 7. PCB assembly.