Total Power International, Inc.
Output Specifications
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise
Temperature Coefficient
Short Circuit Protection
Conditions
Min.
---
For Vin Change of 1%
---
Io=20% to 100%
max. 20MHz Bandwidth
---
---
MBU100 SERIES
DC/DC CONVERTER 1W, SIP-Package
Typ.
Max.
±1.0
±3.0
±1.2
±1.5
See Model Selection Guide
100
150
±0.01
±0.02
0.5 Second Max.
Unit
%
%
mV P-P
%/
General Specifications
Parameter
I/O Isolation Voltage (rated)
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF (calculated)
Conditions
60 Seconds
500 VDC
100KHz, 1V
MIL-HDBK-217F@25, Ground Benign
Min.
Typ.
1000
---
1000
---
---
60
50
90
2,000,000
---
Max.
Unit
---
VDC
---
MΩ
100
pF
110
KHz
---
Hours
Input Fuse
3.3V Input Models
800mA Slow-Blow Type
5V Input Models
500mA Slow-Blow Type
12V Input Models
200mA Slow-Blow Type
24V Input Models
100mA Slow-Blow Type
Environmental Specifications
Parameter
Operating Ambient Temperature Range (See Power Derating Curve)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from case for 10Sec.)
Conditions
Ambient
Min.
Max.
-40
+85
---
+90
-50
+125
---
95
Free-Air convection
---
260
Unit
% rel. H
Power Derating Curve
(5V Output Only)
(All Other Output)
Notes
1 Specifications typical at Ta=+25, resistive load, nominal input voltage and rated output current unless otherwise noted.
2 Ripple & Noise measurement bandwidth is 0-20MHz.
3 These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these
modules; however they may not meet all specifications listed.
4 All DC/DC converters should be externally fused at the front end for protection.
5 Other input and output voltage may be available, please contact factory.
6 That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
7 Specifications are subject to change without notice.
Total Power International, Inc
Toll Free: 877-646-0900
www.total-power.com

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]