3421 AND 3422
HALL-EFFECT,
DIRECTION-DETECTION
SENSORS
MAGNETIC CHARACTERISTICS over operating voltage range.
A3421xKA
Characteristic
Symbol Test Conditions Min. Typ. Max.
Operate Point
Release Point3
BOP
TA = -40°C
140 185 300
TA = +25°C
130 160 280
TA = Maximum
120
260
BRP
TA = -40°C
-300 -190 -140
TA = +25°C
-280 -175 -130
Hysteresis
TA = Maximum -260
-120
Bhys
TA = -40°C
280 375
TA = +25°C
260 335
TA = Maximum
240
Operate Differential
BOP1 - BOP2
±80
Release Differential
BRP1 - BRP2
±80
A3422xKA
Min. Typ. Max.
29
85
29
75
75
-85
-19
-75
-18
-75
-16
10
48
10
46
10
±60
±60
NOTES:1. Magnetic flux density is measured at most sensitive area of device,
nominally located 0.014” (0.37 mm) below the branded face of the package.
2. Typical Data is at VCC = 12 V and TA = +25°C and is for design information only.
3. As used here, negative flux densities are defined as less than zero (algebraic convention).
Units
G
G
G
G
G
G
G
G
G
G
G