DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HCPL-2601 Просмотр технического описания (PDF) - Broadcom Corporation

Номер в каталоге
Компоненты Описание
производитель
HCPL-2601 Datasheet PDF : 30 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
6N137, HCNW137, HCNW2601, HCNW2611, HCPL-0600, HCPL-0601, HCPL-
0611, HCPL-0630, HCPL-0631, HCPL-0661, HCPL-2601, HCPL-2611, HCPL-
2630, HCPL-2631, HCPL-4661 Data Sheet
High CMR, High Speed TTL Compatible Optocouplers
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics2 (HCPL-06xx
Option 060 Only)
Description
Symbol Characteristic Units
Installation classification per DIN VDE 0110, Table 1
for rated mains voltage ≤ 150 Vrms
I-IV
for rated mains voltage ≤ 300 Vrms
I-IV
for rated mains voltage ≤ 600 Vrms
I-III
Climatic Classification
40/85/21
Pollution Degree (DIN VDE 0110/39)
2
Maximum Working Insulation Voltage
VIORM
567
Vpeak
Input-to-Output Test Voltage, Method ba
VPR
1063
Vpeak
VIORM × 1.875 = VPR, 100% Production Test with tm = 1s, Partial Discharge < 5 pC
Input-to-Output Test Voltage, Method aa
VPR
907
Vpeak
VIORM ×1.6 = VPR, Type and Sample Test, tm = 10s, Partial Discharge < 5 pC
Highest Allowable Overvoltage (Transient Overvoltage, tini = 60s)
VIOTM
6000
Vpeak
Safety Limiting Values (Maximum values allowed in the event of a failure)
Case Temperature
Input Currentb
Output Powerb
TS
150
°C
IS,INPUT
150
PS,OUTPUT
600
mA
mW
Insulation Resistance at TS, VIO = 500V
RS
≥ 109
a. Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-5, for
a detailed description.
b. Ratings apply to all devices except otherwise noted in the Package column.
2. Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective
circuits in application.