Contactless reader IC
8.1.2.2 SPI write data
To write data to the MFRC522 using SPI requires the byte order shown in Table 7. It is
possible to write up to n data bytes by only sending one address byte.
The first send byte defines both the mode and the address byte.
Table 7. MOSI and MISO byte order
Line
Byte 0
Byte 1
Byte 2
To
MOSI
address 0 data 0
data 1
...
MISO
X[1]
X[1]
X[1]
...
[1] X = Do not care.
Remark: The MSB must be sent first.
Byte n
data n 1
X[1]
Byte n + 1
data n
X[1]
8.1.2.3 SPI address byte
The address byte must meet the following format.
The MSB of the first byte defines the mode used. To read data from the MFRC522 the
MSB is set to logic 1. To write data to the MFRC522 the MSB must be set to logic 0. Bits 6
to 1 define the address and the LSB is set to logic 0.
Table 8. Address byte 0 register; address MOSI
7 (MSB) 6
5
4
3
2
1
0 (LSB)
1 = read address
0
0 = write
8.1.3 UART interface
8.1.3.1 Connection to a host
MFRC522
RX
RX
TX
TX
DTRQ
MX
DTRQ
MX
001aak587
Fig 8. UART connection to microcontrollers
Remark: Signals DTRQ and MX can be disabled by clearing TestPinEnReg register’s
RS232LineEn bit.