6N137/ SFH6741 / 42 / 50 / 51 / 52
Vishay Semiconductors
IF
B
A
VFF
Dual Channel
1
VCC 8
2
7
3
6
+5V
RL Output VO
Monitoring
0.1 µF Node
Bypass
18977
4
5
GND
VCM
+-
Pulse Generator
ZO = 50
Figure 5. Dual Channel Test Circuit for Common Mode Transient Immunity
Safety and Insulation Ratings
As per IEC60747-5-2, §7.4.3.8.1, this optocoupler is suitable for "safe electrical insulation" only within the safety ratings. Compliance with
the safety ratings shall be ensured by means of protective circuits.
Parameter
Test condition
Symbol
Min
Typ.
Max
Unit
Climatic Classification (according to
IEC 68 part 1)
55/110/21
Comparative Tracking Index
CTI
175
399
VIOTM
8000
V
VIORM
630
V
PSI
500
mW
ISI
300
mA
TSI
175
°C
Creepage
standard DIP-8
7
mm
Clearance
standard DIP-8
7
mm
Creepage
400mil DIP-8
8
mm
Clearance
400mil DIP-8
8
mm
Insulation thickness, reinforced rated per IEC60950 2.10.5.1
0.2
mm
Typical Characteristics (Tamb = 25 °C unless otherwise specified)
1.7
1.6
IF = 50 mA
IF = 20 mA
1.5
1.4
1.3
1.2
IF = 10 mA
1.1
IF = 1 mA
1.0
–40 –20 0 20 40 60 80 100
17610
Tamb – Ambient Temperature ( °C )
Figure 6. Forward Voltage vs. Ambient Temperature
1.60
1.55
1.50
1.45
1.40
1.35
1.30
1.25
1.20
1.15
1.10
0
17611
5 10 15 20 25 30 35 40 45 50
IF – Forward Current ( mA )
Figure 7. Forward Voltage vs. Forward Current