High-ESD Profibus RS-485 Transceiver
ELECTRICAL CHARACTERISTICS (continued)
(VCC = +5V Q10%, TA = TMIN to TMAX, unless otherwise noted. Typical values are at VCC = +5V, TA = +25NC.) (Note 2)
PARAMETER
Maximum Data Rate
Receiver Enable to
Output High
Receiver Enable to
Output Low
Receiver Disable
Time from Low
Receiver Disable
Time from High
SYMBOL
CONDITIONS
tRZH
tRZL
tRLZ
tRHZ
S2 closed; RL = 1kI, CL = 15pF; Figure 10
S1 closed; RL = 1kI, CL = 15pF; Figure 10
S1 closed; RL = 1kI, CL = 15pF; Figure 10
S2 closed; RL = 1kI, CL = 15pF; Figure 10
MIN TYP MAX UNITS
20
Mbps
30
ns
30
ns
30
ns
30
ns
Receiver Enable from
Shutdown to Output
High
tRZL(SHDN)
S1 closed; RL = 1kI, CL = 15pF; Figure 10
(Notes 6, 7)
100
Fs
Receiver Enable from
Shutdown to Output
Low
tRZH(SHDN)
S2 closed; RL = 1kI, CL = 15pF; Figure 10
(Notes 6, 7)
Time to Shutdown
tSHDN
(Note 6)
50
100
Fs
800
ns
Note 2: Devices are production tested at TA = +25NC. Specifications over temperature limits are guaranteed by design.
Note 3: VODPP is the difference in VOD, with the DI at high and DI at low.
Note 4: DVOD and DVOC are the changes in |VOD| and |VOC|, respectively, with the DI at high and DI at low.
Note 5: The short-circuit output current applies to peak current just prior to foldback current limiting; the short-circuit foldback out-
put current applies during current limiting to allow a recovery from bus contention.
Note 6: Shutdown is enabled by bringing RE high and DE low. If the enable inputs are in this state for less than 50ns, the device
is guaranteed not to enter shutdown. If the enable inputs are in this state for at least 800ns, the device is guaranteed to
have entered shutdown.
Note 7: Capacitive load includes test probe and fixture capacitance.
Note 8: Guaranteed by characterization, not production tested.
_______________________________________________________________________________________   5