DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

AD636K Просмотр технического описания (PDF) - Analog Devices

Номер в каталоге
Компоненты Описание
производитель
AD636K Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Data Sheet
Figure 4 shows the value of REXTERNAL for a particular ratio of
VPEAK to −VS for several values of RLOAD. The addition of
REXTERNAL increases the quiescent current of the buffer amplifier
by an amount equal to REXT/−VS. Nominal buffer quiescent
current with no REXTERNAL is 30 µA at −VS = −5 V.
FREQUENCY RESPONSE
The AD636 uses a logarithmic circuit to perform the implicit rms
computation. As with any log circuit, bandwidth is proportional to
signal level. The solid lines in Figure 5 represent the frequency
response of the AD636 at input levels from 1 mV to 1 V rms.
The dashed lines indicate the upper frequency limits for 1%,
10%, and ±3 dB of reading additional error. For example, note
that a 1 V rms signal produces less than 1% of reading additional
error up to 220 kHz. A 10 mV signal can be measured with 1%
of reading additional error (100 µV) up to 14 kHz.
AD636
AC MEASUREMENT ACCURACY AND CREST
FACTOR (CF)
Crest factor is often overlooked in determining the accuracy of
an ac measurement. Crest factor is defined as the ratio of the
peak signal amplitude to the rms value of the signal (CF = VP/V
rms). Most common waveforms, such as sine and triangle
waves, have relatively low crest factors (<2). Waveforms that
resemble low duty cycle pulse trains, such as those occurring in
switching power supplies and SCR circuits, have high crest
factors. For example, a rectangular pulse train with a 1% duty
cycle has a crest factor of 10 (CF = 1/√η).
Figure 6 is a curve of reading error for the AD636 for a
200 mV rms input signal with crest factors from 1 to 7. A
rectangular pulse train (pulse width 200 μs) was used for this
test because it is the worst-case waveform for rms measurement
(all the energy is contained in the peaks). The duty cycle and
peak amplitude were varied to produce crest factors from 1 to 7
while maintaining a constant 200 mV rms input amplitude.
Rev. E | Page 9 of 16