DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

AGN20003X Просмотр технического описания (PDF) - Matsushita Electric Works

Номер в каталоге
Компоненты Описание
производитель
AGN20003X
Nais
Matsushita Electric Works Nais
AGN20003X Datasheet PDF : 4 Pages
1 2 3 4
GN
NOTES
1. Coil operating power
1) As a general rule, only a pure DC pow-
er supply should be used for the coil drive.
2) To ensure proper operation, the voltage
applied to both terminals of the coil should
be ±5% (at 20°C 68°F) the rated operating
voltage of the coil. Also, be aware that the
pick-up and drop-out voltages will fluctu-
ate depending on the ambient tempera-
ture and operating conditions.
3) The ripple factor for the voltage applied
to the coil should be less than 5%.
4) For set and reset latching relays, the
rated operating voltage should be applied
to the coil for 10 ms or more.
2. Coil connection
When connecting coils, refer to the wiring
diagram to prevent mis-operation or mal-
function.
3. External magnetic field
Since GN relays are highly sensitive po-
larized relays, their characteristics will be
affected by a strong external magnetic
field. Avoid using the relay under that con-
ditions.
4. Cleaning
In automatic cleaning, cleaning with the
boiling method is recommended. Avoid ul-
trasonic cleaning which subjects the relay
to high frequency vibrations. It may cause
the contacts to stick.
lt is recommended that a fluorinated hy-
drocarbon or other alcoholic solvent be
used.
5. Packing style
1) The relay is packed in a tube with the
relay orientation mark on the left side, as
shown in the figure below.
Orientation (indicates PIN No.1)stripe
Stopper (green)
Stopper (red)
2) Tape and reel packing
(A type)
(1)-1 Tape dimensions
mm inch
Relay polarity bar
(Z type)
0.40
1.50
+0.1
0
dia
.059
+.004
0
dia
.016
4.00
.157
2.00
.079
11.50
.453
1.75
.069
24.00±0.3
11.10 .945±.012
.437
10.70±0.2
.421±.008
GN relays
2.00dia
.079dia
16.00
8.00
.630
.315
Tape coming out direction
General tolerance ±0.1 mm .004 inch
(S type)
(1)-2 Tape dimensions
Relay polarity bar
(Z type)
2.00
1.50
+0.1
0
dia
.079
.059
+.004
0
dia
4.00 2.0dia
.157 .079dia
1.75
.069
10.70±0.2
.421±.008
0.40
.016
11.50
.453 24.00±0.3
11.10 .945±.012
.437
GN relays
16.00
6.3
.630
.248
Tape coming out direction
General tolerance ±0.1 mm .004 inch
(2) Dimensions of plastic peel
mm inch
21±0.8 dia.
.827±.031 dia.
2.0±0.5
.079±.020
100±1 dia.
3.937±.039 dia.
370±2 dia.
14.567±.079 dia.
13±0.2 dia.
.512±.008 dia.
24.4
+2
0
.961
+.079
0
2.0±0.2
.079±.008
6. Automatic insertion
To maintain the internal function of the
relay, the chucking pressure should not
exceed the values below.
Chucking pressure in the direction A:
4.9 N {500gf} or less
Chucking pressure in the direction B:
9.8 N {1 kgf} or less
Chucking pressure in the direction C:
9.8 N {1 kgf} or less
,,,C
A
B
Please chuck the portion.
Avoid chucking the center of the relay.
In addition, excessive chucking pressure
to the pinpoint of the relay should be
avoided.
For Cautions for Use, see Relay Technical Information (Page 48 to 76).
91/12/82000
All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.
Go To Online Catalog