Electrical Specifications (Tested with HCPL-0872 or Sinc3 Filter)
Unless otherwise noted, all specifications are at VIN+ = -200 mV to +200 mV and VIN- = 0 V; all Typical specifications are
at TA = 25°C and VDD1 = VDD2 = 5 V, and all Minimum and Maximum specifications apply over the following ranges: TA = -
40°C to +85°C, VDD1 = 4.5 to 5.5 V and VDD2 = 4.5 to 5.5 V.
STATIC CHARACTERISTICS
Parameter
Symbol
Min. Typ. Max. Units Conditions
Fig. Note
Resolution
Integral Nonlinearity
15
bits
INL
3
30 LSB
7
58
0.01 0.14 %
68
Differential Nonlinearity
DNL
1
LSB
9
Uncalibrated Input Offset
VOS
-3 0
3
mV
VIN+ = 0 V
7
Offset Drift vs. Temperature
Offset drift vs. VDD1
Internal Reference Voltage
dVOS/dTA
dVOS/dVDD1
VREF
2
10
0.12
320
µV/°C
mV/V
mV
VIN+ = 0 V
VIN+ = 0 V
7 10
7
8
Absolute Reference Voltage
-4
4
%
8
Tolerance
Reference Voltage
Matching
HCPL-7860
HCPL-786J
-1
1
%
TA = 25°C.
8
-2
2
%
See Note 11
VREF Drift vs. Temperature
dVREF/dTA
60
ppm/°C.
8
VREF Drift vs. VDD1
dVREF/dVDD1
0.2
%
8
Full Scale Input Range
-VREF
+VREF mV
Recommended Input Voltage Range
-200
+200 mV
DYNAMIC CHARACTERISTICS (Digital Interface IC HCPL-0872 is set to Conversion Mode 3.)
Parameter
Symbol Min. Typ. Max. Units Conditions
Fig.
Signal-to-Noise Ratio
SNR 62
73
Total Harmonic Distortion
THD
-67
Signal-to-(Noise + Distortion) SND
66
dB
VIN+ = 35 Hz,
9,10
dB
400 mVpk-pk
(141 mVrms)
dB
sine wave.
Effective Number of Bits
ENOB 10
12
bits
11
Conversion Time
tC2
0.2
0.8
µs
Pre-Trigger Mode 2 1,12
tC1
19
23
µs
Pre-Trigger Mode 1 1,12
tC0
39
47
µs
Pre-Trigger Mode 0 1,12
Signal Delay
tDSIG
19
23
µs
13
Over-Range Detect Time
tOVR1
2.0
3.0
4.2
µs
VIN+ = 0 to 400mV 14
Threshold Detect Time
tTHR1
10
µs
step waveform
(default configuration)
Signal Bandwidth
BW
18
22
kHz
15
Isolation Transient Immunity CMR 15
20
kV/µs VISO = 1 kV
Note
12
13
13
14
15
16
17
18
8