DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MCT0603 Просмотр технического описания (PDF) - Unspecified

Номер в каталоге
Компоненты Описание
производитель
MCT0603
ETC2
Unspecified ETC2
MCT0603 Datasheet PDF : 13 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
BCcomponents
Precision flat chip resistors
Product specification
MCT 0603; MCU 0805;
MCA 1206
TESTS AND REQUIREMENTS
All tests are carried out in accordance with the following
specifications:
EN 60115-1, Generic specification (includes tests)
EN 140 400, Sectional specification (includes schedule
for qualification approval)
EN 140 401-801, Detail specification (includes schedule
for conformance inspection)
The components are approved in accordance with the
European CECC-system, where applicable. Table 5 contains
only the most important tests. For the full test schedule refer
to the documents listed above. The testing also covers most
of the requirements specified by EIA/IS-703 and JIS-C-5202.
The tests are carried out in accordance with IEC 60 068 and
under standard atmospheric conditions in accordance with
IEC 60068-1, 5.3. Climatic category LCT/UCT/56 (rated
temperature range: Lower Category Temperature, Upper
Table 5 Test procedures and requirements
Category Temperature; damp heat, long term, 56 days) is
valid.
Unless otherwise specified the following values apply:
Temperature: 15 °C to 35 °C
Relative humidity: 45% to 75%
Air pressure: 86 kPa to 106 kPa (860 mbar to
1 060 mbar).
The components are mounted for testing on boards in
accordance with EN 60 115-1, 4.31 unless otherwise
specified.
The requirements stated in Table 5 are based on the
required tests and permitted limits of EN 140 401-801.
However, some additional tests and a number of
improvements against those minimum requirements have
been included.
EN
60 115-1
CLAUSE
IEC
60 068-2
TEST
METHOD
TEST
PROCEDURE
stability for product
types:
MCT 0603
MCU 0805
4.5
4.8.4.2
4.25.1
MCA 1206
-
resistance
-
temperature at 20 / -10 / 20 °C and
coefficient 20 / 85 / 20 °C
-
endurance at U = P70 ´ R or
70 °C:
U = Umax; whichever is
precision the less severe
operation 1,5 h on; 0,5 h off
mode
70 °C; 1000 h
70 °C; 8000 h
-
endurance at U = P70 ´ R or
70 °C:
U = Umax; whichever is
standard
the less severe;
operation 1,5 h on; 0,5 h off
mode
70 °C; 1000 h
70 °C; 8000 h
REQUIREMENTS
PERMISSIBLE CHANGE (DR/R)
STABILITY
CLASS 0,1
STABILITY
CLASS 0,25
100 W to 10 kW
47 W to < 100 W;
> 10 kW to 150 kW
100 W to 47,5 kW
47 W to < 100 W;
> 47,5 kW to 332 kW
47 W to 332 kW
-
±0,1%; ±0,25%
±25 ppm/K; ±15 ppm/K; ±10 ppm/K
±(0,1%R + 0,02 W)(1)
±(0,2%R + 0,05 W)(1)
±(0,2%R + 0,02 W)(1)
±(0,4%R + 0,05 W)(1)
2002 Dec 19