TSOP344..SS1BS12
Vishay Semiconductors
• Signals from fluorescent lamps with electronic bal-
last with high or low modulation
(see Figure 14 or Figure 15).
40q
1.0
0.9
50q
0.8
60q
70q
0.7
80q
0.6 0.4 0.2 0 0.2 0.4 0.6
96 12223p2
drel – Relative Transmission Distance
Figure 13. Directivity
Suitable Data Format
The circuit of the TSOP348..SS1BS12 is designed in
that way that unexpected output pulses due to noise
or disturbance signals are avoided. A bandpass filter,
an integrator stage and an automatic gain control are
used to suppress such disturbances.
The distinguishing mark between data signal and dis-
turbance signal are carrier frequency, burst length
and duty cycle.
The data signal should fulfill the following conditions:
• Carrier frequency should be close to center fre-
quency of the bandpass (e.g. 38 kHz).
• Burst length should be 10 cycles/burst or longer.
• After each burst which is between 10 cycles and 35
cycles a gap time of at least 14 cycles is necessary.
• For each burst which is longer than 0.9 ms a corre-
sponding gap time is necessary at some time in the
data stream. This gap time should be at least 7 times
longer than the burst.
• Up to 400 short bursts per second can be received
continuously.
Some examples for suitable data format are: NEC
Code, Toshiba Micom Format, Sharp Code, RC5
Code, R-2000 Code.
When a disturbance signal is applied to the
TSOP344..SS1BS12 it can still receive the data sig-
nal. However the sensitivity is reduced to that level
that no unexpected pulses will occur.
Some examples for such disturbance signals which
are suppressed by the TSOP344..SS1BS12 are:
• DC light (e.g. from tungsten bulb or sunlight)
• Continuous signal at 38 kHz or at any other fre-
quency
IR Signal from fluorescent
lamp with low modulation
0
16920
5
10
15
20
Time ( ms )
Figure 14. IR Signal from Fluorescent Lamp with low Modulation
IR Signal from fluorescent
lamp with high modulation
0
16921
5
10
15
20
Time ( ms )
Figure 15. IR Signal from Fluorescent Lamp with high Modulation
Document Number 82272
Rev. 1.1, 28-Feb-05
www.vishay.com