Block diagram
PBA1000F
PBA/PBW
AC IN
85 - 264V
FG
FUSE
250V30A
NOISE
FILTER
RECTIFIER
INRUSH
CURRENT
LIMIT
INVERTER
ACTIVE FILTER
SWITCHING
DEVICE
RECTIFIER
AND
FILTER
VOLTAGE
SENSING
CURRENT
SENSING
CURRENT
SENSING
THERMAL
PROTECTION
CONTROL
CONTROL
VOLTAGE
SENSING
INTERNAL
REGULATOR
FAN
RECTIFIER
AND
FILTER
OVER VOLTAGE
PROTECTION
CONTROL
MASTER
SLAVE
CONTROL
ALARM
DC OUT
±M
±S(REMOTE SENSING)
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
PG(POWER GOOD)
AUX(12 V 0.1A)
External view
15.85
[0.62]
M4 Name plate
Input terminal cover
25max
[0.98]
AC(L)
AC(N)
FG( )
CN3
CN2
CN1
51.25
[2.02]
Name plate
Output voltage
adjustable potentiometer
LED
Output terminal(-)
Output terminal(+)
(35)
[1.38]
29
[1.14]
2-M4
2-º9
[0.35]
165 ±0.5
[6.5] 240
[9.45]
¶ Tolerance : ±1 [±0.04]
7 13
¶ Weight : 2.2kg max
¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]
[0.28] [0.51]
¶ Chassis material : Aluminum
¶ Dimensions in mm, [ ]= inches
¶ Mounting torque : 1.2N • m(12.8kgf • cm)max
¶ Screw tightening torque : 1.6N • m(16.9kgf • cm)max
¶ The housing for the remote sensing unused is mounted on CN1
¶ Please connect safety ground to FG terminal on the unit.
29
[1.14]
165±0.5
[6.5]
4-M4
Mounting Hole
(Bottom side)
6max
[0.24]
8-M4
Mounting Hole
(Both side)
AIR FLOW
PPBBAA//PPBBWW--2211