ZiLOG
STANDARD TEST CONDITIONS
The characteristics listed below apply for standard test con-
ditions as noted. All voltages are referenced to Ground. Pos-
itive current flows into the referenced pin (Figure 7).
From Output
Under Test
Z8E001
Z8Plus OTP Microcontroller
150 pF
Figure 7. Test Load Diagram
CAPACITANCE
TA = 25¡C, VCC = GND = 0V, f = 1.0 MHz, unmeasured pins returned to GND.
Parameter
Input capacitance
Output capacitance
I/O capacitance
Min
Max
0
12 pF
0
12 pF
0
12 pF
DS001101-Z8X0400
PRELIMINARY
9