DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

CINT3110A0508K01 Просмотр технического описания (PDF) - Unspecified

Номер в каталоге
Компоненты Описание
производитель
CINT3110A0508K01
ETC
Unspecified ETC
CINT3110A0508K01 Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
CINT3110 Family
110W Triple Output
Industrial Grade
INPUT
AC Input
Input Current
Inrush Current
Input Fuses
Earth Leakage Current
Efficiency
100-240Vac, ±10%, 47-63Hz, 1Ø 120–370Vdc
115Vac: 1.5A, 230Vac: 0.75A
264Vac, cold start: will not exceed 45A
F1, F2: 2.5A, 250Vac fuses provided on all models
<290μA@264Vac, 60Hz, NC
87% typical at 230Vac
SAFETY
Safety Standards
EN/CSA/UL/IEC 60950-1, 2nd Edition
OUTPUT
Output Voltage
Output Power
Turn On Time
Hold-up Time
Ripple and Noise
Total Regulation
Switching Frequency
Transient Response
Minimum Load
See models chart
110W continuous with 200 lfm airflow, 80W
convection cooled – See chart for specific voltage
model ratings
Less than 2 sec. @115Vac (inversely proportional to
input voltage and thermistor temperature)
16mS typical at 110W, 120Vac input
See models chart
See models chart
PFC: 75kHz typical
500μS typ. for return to within 0.5% of nominal, 50%
load step. Di/Dt <0.2A/μS, Max Volt Deviation = 3%
Not required
ENVIRONMENT
Operating Temperature -10°C to +70°C
Relative Humidity
5% to 95%, non-condensing
Weight
140g, typical
Dimensions
Temperature Derating
Altitude
W: 2.0” x L: 4.0” x H: 1.3”
Derate output power linearly above 50°C to 50%
at 70°C
Operating: -500 to 10,000 ft. Non-operating: -500 to
40,000 ft.
Storage Temperature -40°C to +85°C
Vibration
Shock
Operating: 0.003g²/Hz, 1.5grms overall, 3 axes, 10
min/axis
Non-Operating: 0.026g²/Hz, 5.0grms overall, 3 axes,
1 hr/axis
Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks
total
Non-Operating: Half-sine, 40 gpk, 10 ms, 3 axes, 6
shocks total
EMI/EMC COMPLIANCE
Conducted Emissions
Radiated Emissions
Static Discharge Immunity
Radiated RF Immunity
EFT/Burst Immunity
Line Surge Immunity
Conducted RF Immunity
Power Frequency Magnetic
Field Immunity
Voltage Dip Immunity
Line Harmonic Emissions
Flicker Test
EN55011/22 Class B, FCC Part 15, Subpart B,
Class B
EN55011/22 Class A; FCC Part 15, Subpart A,
Class A
EN61000-4-2, Criteria A, 6kV Contact Discharge,
8kV air discharge
EN61000-4-3, 3V/m. Criteria A
EN61000-4-4, 2kV/5kHz, Criteria A
EN61000-4-5, 1kV differential, 2kV
common-mode, Criteria A
EN61000-4-6, 3Vrms, Criteria A
EN61000-4-8, 3A/m, Criteria A
EN61000-4-11, 0% Vin, 0.5cycle; 40% Vin, 5
cycles; 70% Vin, 25 cycles; Criteria A
EN61000-3-2, Class A, B, C, & D
EN61000-3-3, Complies (dmax<6%)
ISOLATION
Isolation
Input-Output: 4000Vac
Input-Ground: 1800Vac
Output-Ground: 500Vac
RELIABILITY
MTBF
245,000 hours, 25°C Ambient, 110Vac input
PROTECTION
Overvoltage Protection
Short Circuit Protection
Overload Protection
See models chart for trip range
Provided - no damage will occur if the output is
shorted
150%-300% above rating for V2 & V3, 110%-
200% for V1. Hiccup Mode
Notes:
1. Specifications are for convection rating at factory settings at 115 Vac input, 25°C ambient
unless otherwise stated
2. For DC input an external DC safety rated fuse must be used
CINT3110 Datasheet v0818
Copyright © 2018 SL Power Electronics Corp. - All rights reserved.
Page 2