RT9519A
Parameter
PGOOD Deglitch Time
Input Over Voltage Blanking
Time
Pre-Charge to Fast-Charge
Deglitch Time
Fast-Charge to Pre-Charge
Deglitch Time
Termination Deglitch Time
Recharge Deglitch Time
Input Power Loss to SYS LDO
Turn-Off Delay Time
Pack Temperature Fault
Detection Deglitch Time
Short Circuit Deglitch Time
Short Circuit Recovery Time
Other
VP (External used only)
VP Under Voltage Lockout
Threshold
TS Battery Detect Threshold
NTC
Low Temperature Trip Point
Low Temperature Trip point
Hysteresis
High Temperature Trip Point
High Temperature Trip Point
Hysteresis
Symbol
Test Conditions
Min Typ Max
Time measured from VIN :
tPGOOD
0Æ5V
--
1
--
1μs rise-time to PGOOD = L
tOVP
--
50
--
tPF
--
25
--
tFP
tTERMI
tRECHG
tNO_IN
--
25
--
--
25
--
--
100
--
--
25
--
tTS
tSHORT
tSHORT-R
--
25
--
--
250
--
--
64
--
Unit
s
μs
ms
ms
ms
ms
ms
ms
μs
ms
VVP
Falling Threshold
VTS
2.95 --
3.6
V
--
0.8
--
V
2.75 2.85 2.95
V
VCOLD
ΔVCOLD
VHOT
ΔVHOT
Rising Threshold
Falling Threshold
58.8 60 61.2 % of VP
--
1.5
-- % of VP
35.8 37.5 39.1 % of VP
--
1.5
-- % of VP
Note 1. Stresses listed as the above "Absolute Maximum Ratings" may cause permanent damage to the device. These are for
stress ratings. Functional operation of the device at these or any other conditions beyond those indicated in the
operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended
periods may remain possibility to affect device reliability.
Note 2. Guraranteed by design.
Note 3. θJA is measured in natural convection at TA = 25°C on a high effective thermal conductivity four-layer test board of
JEDEC 51-7 thermal measurement standard. The measurement case position of θJC is on the exposed pad of the
package.
Note 4. Devices are ESD sensitive. Handling precaution is recommended.
Note 5. The device is not guaranteed to function outside its operating conditions.
www.richtek.com