µPC2782GR
Standard Characteristics (TA = 25 °C, VCC = 5 V)
Parameter
Mixer Section
Input Intercept Point 1
Input Intercept Point 2
Third Intermodulation
Distortion 1
Third Intermodulation
Distortion 2
Oscillator Output Power
Oscillator Frequency Range
IF Amp. Section
Output Intercept Point
Symbol
Reference Value
MIN. TYP. MAX.
UNIT
Test Conditions
IIP31
IIP32
IM31
IM32
POSC
fOSC
−
0
−
dBm fRF = 900, 930 MHz, fOSC = 1 380 MHz
POSC = −10 dBm
*6
−
+4.5
−
dBm fRF = 2.1, 2.13 GHz, fOSC = 2.58 GHz
POSC = −10 dBm
*6
−
50
−
dBc fRF = 900, 930 MHz, PRF = −25 dBm each
fOSC = 1 380 MHz, POSC = −10 dBm *6
−
59
−
dBc fRF = 2.1, 1.13 GHz, PRF = −25 dBm each
fOSC = 2.58 GHz, POSC = −10 dBm *6
−
−15
−
dBm
*7
1.3
−
2.6
GHz
*7
OIP3
−
+15.5
−
dBm fIF = 480, 510 MHz
*8
*6 by measurement circuit 3
*7 by application circuit example
*8 by measurement circuit 6
Data Sheet P11758EJ3V0DS00