Data Sheet
Parameter
Min
RIGHT LEG DRIVE/DRIVEN LEAD
Output Voltage Range
0.2
RLD_OUT Short-Circuit Current −5
Closed-Loop Gain Range2
25
Slew Rate2
Input Referred Noise1
Amplifier GBP2
DC LEAD-OFF
Lead-Off Current Accuracy
High Threshold Level1
Low Threshold Level1
Threshold Accuracy
AC LEAD-OFF
Frequency Range
Lead-Off Current Accuracy
REFIN
Input Range2
1.76
Input Current
450
REFOUT
Output Voltage, VREF
Reference Tempco1
Output Impedance2
Short-Circuit Current1
Voltage Noise1
CALIBRATION DAC
DAC Resolution
Full-Scale Output Voltage
Zero-Scale Output Voltage
DNL
Output Series Resistance2
Input Current
CALIBRATION DAC TEST TONE
Output Voltage
Square Wave
Low Frequency Sine Wave
High Frequency Sine Wave
SHIELD DRIVER
Output Voltage Range
Gain
Offset Voltage
Short-Circuit Current
Stable Capacitive Load2
CRYSTAL OSCILLATOR
Frequency2
Start-Up Time2
1.785
2.64
0.24
−1
0.9
0.3
−20
Typ
±2
200
8
1.5
±10
2.4
0.2
25
2.039
±10
1.8
113
675
1.8
±10
0.1
4.5
33
17
10
2.7
0.3
10
±5
1
1
10
150
1
15
8.192
15
ADAS1000-3/ADAS1000-4
Max
Unit
AVDD − 0.2 V
+5
mA
V/V
mV/ms
μV p-p
MHz
%
V
V
mV
kHz
%
1.84
V
μA
950
μA
1.815
2.76
0.36
+1
1.1
2.3
+20
25
10
V
ppm/°C
Ω
mA
μV p-p
μV p-p
Bits
V
V
LSB
nA
mV p-p
Hz
Hz
Hz
V
V/V
mV
μA
nF
MHz
ms
Test Conditions/Comments
External protection resistor required to meet
regulatory patient current limits; output shorted to
AVDD/AGND
0.05 Hz to 150 Hz
Internal current source, pulls up open ECG pins;
programmable in 10 nA steps: 10 nA to 70 nA
Of programmed value
Inputs are compared to threshold levels; if inputs
exceed levels, lead-off flag is raised
Programmable in 4 steps: 12.5 nA rms, 25 nA rms,
50 nA rms, 100 nA rms
Fixed frequency
Of programmed value, measured into low impedance
Channel gain scales directly with REFIN
Per active ADC
Three ECG channels and respiration enabled
On-chip reference voltage for ADC; not intended to
drive other components reference inputs directly,
must be buffered externally
Short circuit to ground
0.05 Hz to 150 Hz (ECG band)
0.05 Hz to 5 Hz (respiration)
Available on CAL_DAC_IO (output for master, input for
slave)
No load, nominal FS output is 1.5 × REFOUT
No load
Not intended to drive low impedance load, used for
slave CAL_DAC_IO configured as an input
When used as an input
Rides on common-mode voltage, VCM_REF = 1.3 V
Rides on common-mode voltage (VCM)
Output current limited by internal series resistance
Applied to XTAL1 and XTAL2
Internal startup
Rev. B | Page 7 of 80