DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

JSM1-12V-4 Просмотр технического описания (PDF) - Matsushita Electric Works

Номер в каталоге
Компоненты Описание
производитель
JSM1-12V-4
Nais
Matsushita Electric Works Nais
JSM1-12V-4 Datasheet PDF : 4 Pages
1 2 3 4
JS-M
1-(3) Electrical life test (Door lock motor load)
Tested sample: JSM1-12V-4, 10 pcs.
Load: DC 16 V Max. 17.7 A, Min. 15.2 A
Switching frequency: 6 cycles/min.
(ON:OFF = 0.5:0.5 s)
Ambient temperature: 30°C 86°F
Tested cycle: 4 × 104 cycles
Circuit
+
16 V DC
MMMM
Contact welding
detection and
Mis-contacting
detection circuit
Change of pick-up and drop-out voltage
10
9
8
7
6
Pick-up voltage
Max.
x
Min.
5
4
Drop-out voltage
3
Max.
x
2
Min.
1
0
2
4
No. of operations, ×104
1-(4) Electrical life test
Tested sample: JSM1-12V-4, 3 pcs.
Load: 16 V DC 25 A/5 A motor load
Switching frequency: 6 cycles
(ON:OFF = 1:9 s)
Ambient temperature: 27°C 81°F
Circuit
+
16 V
DC
12 V DC
Detection circuit
Contact welding:
M
Min. 0.5 s
Mis-contacting:
After 0.2 s
Change of pick-up and drop-out voltage
6
Pick-up voltage
5
Max.
x
4
Min.
3
Drop-out voltage
2
1
Max.
x
Min.
0
10
No. of operations, ×104
Change of contact resistance
100
90
N.C. side
N.O. side
80
70
60
50
40
30
20
10
x
x
0
2
4
No. of operations, ×104
Change of contact resistance
14 N.O. side
12
10
8
6
4
2
0
No. of operations, ×104
Max.
x
Min.
10
1-(5) Electrical life test
Tested sample: JSM1-12V-5, 4 pcs.
Load: 16 V DC 15 A (resistive)
Switching frequency: 20 cpm
Ambient temperature: 25°C 77°F
Circuit
+
16 V
DC
12 V DC
Detection circuit
Contact welding:
Min. 0.5 sec.
Mis-contacting:
After 0.2 sec.
Change of pick-up and drop-out voltage
6
5
Pick-up voltage
Max.
4
x
Min.
3
2
Drop-out voltage
Max.
x
Min.
1
0
10
No. of operations, ×104
Change of contact resistance
14 N.O. side
12
10
8
6
4
2
0
No. of operations, ×104
Max.
x
Min.
10
1-(6) Electrical life test
Tested sample: JSM1-12V-5, 3 pcs.
Load: 16 V DC 50 A/10 A motor load
Switching frequency: 6 cycles
(ON:OFF = 1:9 s)
Ambient temperature: 27°C 81°F
Circuit
+
16 V
DC
12 V DC
Detection circuit
Contact welding:
M
Min. 0.5 s
Mis-contacting:
After 0.2 s
Change of pick-up and drop-out voltage
6
5
Pick-up voltage
Max.
4
x
Min.
3
Drop-out voltage
Max.
2
x
Min.
1
0
10
No. of operations, ×104
Change of contact resistance
14 N.O. side
12
10
8
6
4
2
0
No. of operations, ×104
Max.
x
Min.
10
362