DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

CE-0931 Просмотр технического описания (PDF) - TDK Corporation

Номер в каталоге
Компоненты Описание
производитель
CE-0931
TDK
TDK Corporation TDK
CE-0931 Datasheet PDF : 6 Pages
1 2 3 4 5 6
CE-09xx
2
CE-09xx Specifications
ITEMS/UNIT
MODEL
CE-0926
CE-0927
CE-0928
Discontinued
CE-0929
Discontinued
CE-0930
CE-0931
CE-0932
CE-0925A
CE-0928LC
CE-0952
Nominal Voltage
V DC3.3/5.0 DC3.3 DC5 DC3.3/5.0 DC3.3
DC3.3/5.0
Input Voltage Range
V DC3.0-5.5 DC3.0-3.6 DC4.5-5.5 DC3.0-5.5 DC3.0-3.6
DC3.0-5.5
Efficiency (typ)
(*1)
80
88 67
83
72 50 92 50
Nominal Voltage
VDC 12.0 2.0 3.3 -2.0 5.0 15.0 -5.0 75 3.3 60
Maximum Current
(*2) mA 50/ch
600
300
40/ch 200 2 1200 2
Maximum Power
(*3) W
1.2
1.98 0.6 1.5 1.2 1.0 0.15 3.96 0.12
Output Max Power Total Regulation (max) (*4)
5
4
5
4
5
Maximum Ripple & Noise (typ) (*5) mVp-p
50
20
Maximum Ripple & Noise (max)(*5) mVp-p
100
150 100 150
Voltage Adjustable Range VDC Fixed 1.0-2.0 2.0-3.3 -1.8--2.5 4.0--5.8 Fixed -4.0--5.5 50-100 1.5-3.3 40-80
Over Current Protection
Not available
Available
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Storage Temperature
Environment
Operating Humidity
Storage Humidity
Vibration
Shock
Mechanical
Weight
Size (W
x
H
x
D)
Not available
Not available
-40 to +85
-40 to +85
RH 10-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
RH 10-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
10-2000Hz, 4 minutes sweep and 98m/s² (10G) acceleration, 3 directions, 0.5h for each, in non-operation
980m/s² (100G), 6ms, 3 directions, 3 times for each, in non-operation
g
1.5
mm
18 x 4 x 11.8
(*1)
(*2) For the output side (Io2) of dual-output models (CE-0926/0931), refer to the items of output voltage setting in the instructions.
(*3) The maximum output power value is that of nominal output voltage x maximum output current.
(*4) Max power total regulation (% ) is the regulation of the set output voltage including load change, input change, and temperature change.
  Condition of Io2 for dual-output models (CE-0926/0931): 0.5 x Io1 < Io2 < 1.5 x Io2
(*5)
°C, if not specified separately.
Metal case
Outline Drawing
8-ø0.8
Cut-through hole
1.3
1
CE-09xx
8
2
TDK-Lambda
7
3
MADE IN JAPAN
6
4
Lot No.
5
Recommended measurements for board
mounting Pattern prohibited 1.4
1.6
area (CE-0929 only)
1
18±0.3
P=2±0.3
Unit: mm
Pattern (resist processing)
15.4
(19.4)
Dimensions in m
12
9.4
2
Case is connected to GND.
Derating Curve
100
80
60
40
20
・All specifications are subject to change without notice.
0–40
0
50
80
Ambient temperature (°C)
Output power derating by ambient temperature

Share Link: 