4 | C-Series Circuit Breaker - General Specifications
Electrical Tables
Table B: Lists UL Recognized and CSA Accepted configurations and performance capabilities as a Manual Motor Controller.
Circuit
Configuration
Series,
Shunt &
Relay Switch
Only
C-SERIES TABLE B: Manual Motor Controllers
Voltage
Current Rating
Horsepower Ratings
Max. Rating Frequency Phase Full Load Amps
Max. HP
120 1
50 / 60
1
0.02 - 50
7 1/2
250 1
1
50 / 60
0.02 - 20
3
3
0.02 - 20
5
277 1
50 / 60
1
0.02 - 20
3
480 2
50 / 60
3
0.02 - 20
5
Notes:
1. Requires branch circuit backup with a UL Listed
Type K5 or RK5 fuse rated 15A Minimum and no
more than 4 times full load amps not to exceed
125A for 50 Amp or less rating and not to exceed
175A for 51 through 100A rating.
2. UL Recognized and CSA Certified at 480V refers
to 3 and 4 pole versions used in a 3Ø, WYE
connected circuit or a 2 pole version with 2 poles
breaking 1Ø and backed up with a series fusing as
stated in note 1.
* Shunt and Relay Trip - Voltage Coil
Construction not current coils
Table C: Lists UL Recognized, CSA Accepted, VDE and TUV Certified configurations and performance capabilities as a
Component Supplementary Protector.
C-SERIES TABLE C: Component Supplementary Protectors
Voltage
Current Rating
Short Circuit Capacity (Amps)
Circuit
Configuration
Max.
Rating
Frequency
Phase
Full
Load
Amps
UL / CSA
VDE
TUV
General
Purpose
Amps 1
With
Backup
Fuse
Without
Backup
Fuse
(Inc)
With
Backup
Fuse
(Icn)
Without
Backup
Fuse
(Inc)
With
Backup
Fuse
(Icn)
Without
Backup
Fuse
Application
Codes
UL / CSA
Construction Notes
--- 0.10 - 70 ---
--- 7,500 --- 5,000 5,000 1,500 TC1,2,OL1,U1
---
80
DC
--- 71 - 100 71 - 100 --- 10,000 --- 5,000 --- 5,000 TC1,2,OL0,U1 Agency F, H, J or R
125
DC
--- 1 - 50
---
--- 5,000 ---
---
--- 5,000 TC1,2,OL1,U1
Agency J or R
DC
--- 0.10 - 50
---
---
--- 5,000
2P, Agency J or R
Series
250
50 / 60
1 0.10 - 70 ---
0.10 - 100
3 0.10 - 90
--- 5,000 3,000 1,500 3,000 1,500 TC1,2,OL1,U1
---
---
5,000 5,000
---
---
---
Agency J or R
415 50 / 60
3 0.10 - 30
---
5,000 2 ---
3,000 1,500
3,000 1,500 TC1,2,OL1,C1
Rocker
5,000 2,500
Handle, Agency F, H, J or R
80
DC
---
7,500 ---
5,000
Dual Coil
0.10 - 30 ---
---
1,500
1,500 TC1,2,OL1,U1
---
250 50 / 60 1 & 3
5,000 3,000
3,000
80
DC
--- 0.10 - 70 ---
--- 7,500 --- 5,000 5,000 1,500 TC1,2,OL1,U1
---
Shunt
250 50 / 60 1 & 3 0.10 - 70 ---
--- 5,000 3,000 1,500 3,000 1,500 TC1,2,OL1,U1
---
415 50 / 60
3 0.10 - 30
---
5,000 2 ---
3,000 1,500
3,000 1,500 TC1,2,OL1,C1
Rocker
5,000 2,500
Handle, Agency F, H, J or R
Notes:
1. General Purpose ratings for UL/CSA only.
2. Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less
rating and not to exceed 175 for 51 through 100 Amp rating.
Table D: Lists UL Listed (489), CSA Certified (C22.2 No. 5.1-M) configuration and performance capabilities as a Molded Case
Circuit Breaker.
C-SERIES TABLE D: UL489 Listed Branch Circuit Breakers
Circuit
Voltage
Current Rating Interrupting Capacity (Amps)
Configuration Max. Rating Frequency Phase Full Load Amps Without Backup Fuse
Construction Notes
Series
80
DC
---
125
DC
---
125 / 250 DC
---
120
50 / 60 1
120 / 240 50 / 60 1
240
50 / 60 1
277
50 / 60 1
0.10 - 100
101 - 150
151 - 250
0.10 - 100
0.10 - 50
0.10 - 50
51 - 70
0.10 - 50
0.10 - 30
0.10 - 20
0.10 - 20
50,000 1
10,000
10,000
10,000
5,000
5,000
10,000
5,000
5,000
10,000 1
5,000
10,000
10,000
Limited to 2 Poles Max from 71 - 100 Amps
2 Poles - Parallel Poles
3 Poles - Parallel Poles
1 - 3 Poles
1 or 2 Poles (2 poles required for 250 Volts)
1 - 3 Poles
2 or 3 Poles (1 pole of a 3 pole unit is neutral)
1 Pole
2 Poles
1-2 Poles
Dual Coil
120
50 / 60 1
0.10 - 30
10,000
---
Notes:
1 Special catalog
number required.
Consult factory.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com

Share Link: 