DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

DZ-10G-1A Просмотр технического описания (PDF) - OMRON Corporation

Номер в каталоге
Компоненты Описание
производитель
DZ-10G-1A
Omron
OMRON Corporation Omron
DZ-10G-1A Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
Specifications
Characteristics
Operating speed
Operating frequency
Contact resistance
Insulation resistance
Mechanical
Electrical
Dielectric strength
Vibration resistance
Malfunction
Shock resistance
Destruction
Malfunction
Degree of protection
Degree of protection against electric shock
Proof tracking index (PTI)
Ambient operating temperature
Ambient operating humidity
Service life
Mechanical
Electrical
Weight
Note: 1. The values are for pin plunger models.
2. Malfunction: 1 ms max.
0.1 mm to 1 m/s (See note 1)
240 operations/min
20 operations/min
15 mΩ max. (initial value)
100 MΩ min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 min between non-continuous terminals
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying
metal part, and between current-carrying metal part and ground and between switches
10 to 55 Hz, 1.5-mm double amplitude (See note 2)
1,000 m/s2 max.
300 m/s2 max. (See notes 1 and 2)
IP00
Class I
175
25°C to 80°C (with no icing)
35% to 85%RH
1,000,000 operations min.
500,000 operations min.
Approx. 30 to 50 g
Ratings
Rated voltage
(V)
125 VAC
250 VAC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Non-inductive load (A)
Resistive load
Lamp load
NC
NO
NC
NO
10
2
1
10
1.5
0.7
10
3
1.5
10
3
1.5
10
3
1.5
0.5
0.5
0.25
0.25
Note: 1. The above values are for steady-state current.
2. Inductive load has a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
Inductive load (A)
Inductive load
Motor load
NC
NO
NC
NO
6
3
1.5
4
2
1
6
5
2.5
6
5
2.5
4
3
1.5
0.05
0.05
0.03
0.03
4. Motor load has an inrush current of 6 times the steady-state current.
5. The ratings values apply under the following test conditions:
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency: 20 operations/min
Contact Specifications
Safety Standard Ratings
Contacts
Material
Gap (standard value)
NC
Inrush current
NO
Silver alloy
0.5 mm
30 A max.
15 A max.
UL/CSA
Rated voltage
125 VAC
250 VAC
480 VAC
125 VDC
250 VDC
DZ-10G
10 A and 1/8 HP
10 A and 1/4 HP
2A
0.5 A
0.25 A
90
Special-purpose Basic Switch DZ