M25P10-A
DC and AC parameters
Table 20.
AC Characteristics (50MHz Operation, Device Grade 6)
50MHz available only in products with Process Technology code X(1)
Test conditions specified in Table 10 and Table 12
Symbol
fC
Alt.
Parameter
Min.
Clock Frequency(1) for the following instructions:
fC FAST_READ, PP, SE, BE, DP, RES, WREN, WRDI, D.C.
RDID, RDSR, WRSR
Typ. Max. Unit
50 MHz
fR
tCH(2)
tCL(2)
tCLCH(3)
tCHCL(3)
Clock Frequency for READ instructions
tCLH Clock High Time
tCLL Clock Low Time
Clock Rise Time(4) (peak to peak)
Clock Fall Time(4) (peak to peak)
D.C.
9
9
0.1
0.1
tSLCH tCSS S Active Setup Time (relative to C)
5
tCHSL
S Not Active Hold Time (relative to C)
5
tDVCH tDSU Data In Setup Time
2
tCHDX tDH Data In Hold Time
5
tCHSH
S Active Hold Time (relative to C)
5
tSHCH
S Not Active Setup Time (relative to C)
5
tSHSL tCSH S Deselect Time
100
tSHQZ(3) tDIS Output Disable Time
tCLQV
tV Clock Low to Output Valid
tCLQX tHO Output Hold Time
0
tHLCH
HOLD Setup Time (relative to C)
5
tCHHH
HOLD Hold Time (relative to C)
5
tHHCH
HOLD Setup Time (relative to C)
5
tCHHL
HOLD Hold Time (relative to C)
5
tHHQX(3) tLZ HOLD to Output Low-Z
tHLQZ(3) tHZ HOLD to Output High-Z
tWHSL(5)
Write Protect Setup Time
20
tSHWL(5)
Write Protect Hold Time
100
tDP(3)
S High to Deep Power-down Mode
tRES1(3)
S High to Standby Mode without Electronic
Signature Read
20 MHz
ns
ns
V/ns
V/ns
ns
ns
ns
ns
ns
ns
ns
8 ns
8 ns
ns
ns
ns
ns
ns
8 ns
8 ns
ns
ns
3
µs
30 µs
tRES2(3)
S High to Standby Mode with Electronic Signature
Read
30 µs
1. Details of how to find the process on the device marking are given in Application Note AN1995.
2. tCH + tCL must be greater than or equal to 1/ fC
3. Value guaranteed by characterization, not 100% tested in production.
4. Expressed as a slew-rate.
5. Only applicable as a constraint for a WRSR instruction when SRWD is set at 1.
41/49

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]