ABSOLUTE MAXIMUM RATINGS*
+VS to –VS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 V
Power Dissipation (25°C) . . . . . . . . . . . . . . . . . . . . . . 600 mW
Storage Temperature Range . . . . . . . . . . . . . –65°C to +150°C
Lead Temperature Range (Soldering 10 sec) . . . . . . . . . 300°C
Package Thermal Resistance (JA/JC) . . . . . . . . 90°C/25°C/W
Output Protection: All Outputs Safe if Shorted to Ground
*Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those indicated in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
AD588
PIN CONFIGURATION
A3 OUT FORCE 1
16 –VS
+VS 2
15 A4 OUT FORCE
A3 OUT SENSE 3
14 A4 OUT SENSE
A3 IN 4 AD588 13 A4 IN
TOP VIEW
GAIN ADJ 5 (Not to Scale) 12 BAL ADJ
VHIGH 6
NOISE 7
REDUCTION
VLOW 8
11 VCT
10 GND SENSE –IN
9 GND SENSE +IN
ORDERING GUIDE
Part Number1 Initial Error (mV) Temperature Coefficient2 Temperature Range (°C)
Package Option
AD588AQ
3
AD588BQ
1
AD588JQ
3
AD588KQ
1
3 ppm/°C
1.5 ppm/°C
3 ppm/°C
1.5 ppm/°C
–25 to +85
–25 to +852
0 to 70
0 to 70
CERDIP (Q-16)
CERDIP (Q-16)
CERDIP (Q-16)
CERDIP (Q-16)
NOTES
1For details on grade and package offerings screened in accordance with MIL-STD-883, refer to the Analog Devices Military Products Databook or current
AD588/883B.
2Temperature coefficient specified from 0°C to 70°C.
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although the
AD588 features proprietary ESD protection circuitry, permanent damage may occur on devices
subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended
to avoid performance degradation or loss of functionality.