Single-/Dual-Input 1-Cell Li+ Chargers with
OVP Protection and Programmable Charge Timer
Typical Operating Characteristics (continued)
(VDC = 5V, RSETI = 2kΩ, VBAT = 3.6V, MAX8601 evaluation kit with thermal resistance of 50°C/W. TA = +25°C, unless otherwise noted.)
CHARGE CURRENT vs. AMBIENT
TEMPERATURE (1A CHARGE)
1100
1000
VBAT = 4V
900
800
700
VBAT = 3.6V
600
500
400
300
200
100
-40 -15
RSETI = 1.5kΩ
10
35
60
85
TA (°C)
FAST-CHARGE TIME vs. CCT
800
700
600
500
400
300
200
100
0
0.010
0.045
0.080
CCT (μF)
0.115
0.150
PIN
MAX8600 MAX8601
1
1, 7
2
2
3
3
4
4
5
5
6, 7, 9
8
8
10
10
11
11
Pin Description
NAME
FUNCTION
BAT
SETI
THM
GND
CT
N.C.
EN
POK
CHG
Battery Connection. The IC delivers charging current and monitors battery voltage using BAT.
Bypass BAT to GND with a 2.2µF or larger ceramic capacitor. Connect both BAT inputs
together externally (MAX8601). BAT is high impedance when the IC is disabled.
DC Charge-Current Programming Input. Connect a resistor from SETI to GND to set the
maximum charging current when using the DC input, the prequal current from either input,
and the CHG turn-off threshold.
Thermistor Input. Connect a 10kΩ NTC thermistor, in close proximity to the battery, from THM
to ground to monitor the battery temperature. Connect THM to GND to disable the thermistor
functionality. The IC suspends charging when RTHM is outside the hot and cold limits.
Ground
Timing Capacitor Input. Connect a capacitor from CT to GND to set the precharge timeout,
top-off time, and fast-charge timeout. Connect CT to GND to disable the timers.
No Connection. Make no external circuit connection.
Active-Low Enable Input. Drive low or connect EN to GND to enable the charger. Drive EN
high to disable the charger.
Power-OK Monitor. POK is an open-drain output that pulls low when a valid charging source is
detected at either DC or USB (MAX8601). POK is high impedance when EN is high.
Charging-Status Output. CHG goes low when the battery is above 3V and being charged with
a current greater than 7.5% of the current programmed with RSETI. CHG is high impedance
when the charger is in prequal, top-off, or disabled.