MAP30/40/42 AC-DC Series Data Sheet
Input Specifications
PARAMETER
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
CONDITIONS/DESCRIPTION
Continuous input range.
MAP42
MAP30, MAP40
AC input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Nominal AC Input Voltage (115VAC), full rated load.
90 VAC (40W load).
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C.
Switching frequency of power supply (fixed frequency).
Output Specifications
PARAMETER
Efficiency
Minimum Loads
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
CONDITIONS/DESCRIPTION
Full load, 120VAC.
Single output models; MAP30, MAP42.
All multiple output models, see regulation graphs.
Full load, 20 MHz bandwidth.
Multiple output models with convection cooling.
Output voltage overshoot/undershoot at turn-on, V1.
Varies by output, total regulation includes: Line changes from 90-132
VAC or 175-264, changes in load starting at 20% load and changing
to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output only of multiple output units).
Time required for initial output voltage stabilization.
Turn-on Rise Time
Time required for output voltage to rise from 10% to 90%.
Interface Signals and Internal Protection
PARAMETER
Overvoltage
Protection
Overload
Protection
Remote Sense
CONDITIONS/DESCRIPTION
MAP30-1005, MAP42-1005
MAP42-1012
MAP42-1024
Main output only of multiple output units.
Fully protected against output overload and short circuit. Automatic
recovery upon removal of overload condition.
Total cable drop, single output models only.
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Dielectric Withstand
Voltage
Electromagnetic
Interference
Input Transient
Protection
Insulation Resistance
Leakage Current
CONDITIONS/DESCRIPTION
UL60950.
CSA 22.2 No. 60950.
EN60950 (TUV).
Input to output.
FCC CFR title 47 part 15 sub-part B - conducted.
EN55022 / CISPR 22 conducted (Note 1).
EN55022 / CISPR 22 radiated (Note 2).
EN61000-4-5 Level 3
Line to Line
Line to Ground
Input to output.
Per EN60950, 264VAC
MAP42, MAP40-3100, 3001, 3105, 3500
MAP30-1005, MAP40-3000, MAP40-3003
NOTES: 1) MAP30-1005, MAP40-3000, MAP40-3003 meet Class A.
2) MAP40-3000, MAP40-3003, MAP3500 meet Class A.
MIN
NOM
MAX
UNITS
85
264
VAC
90
264
47
63
Hz
85
VAC
15
ms
1.2
ARMS
38
APK
23
25
30
kHz
MIN
NOM
MAX
UNITS
70
%
0.0
Amps
See Model Selection Chart.
40
Watts
1
%
See regulation graphs.
500
μs
1
2
Sec
20
ms
MIN
NOM
MAX
UNITS
5.8
6.8
20.0
22.0
V
32.0
37.0
5.8
6.8
130
%
250
mV
MIN
2600
1
2
7
NOM
MAX
Approved.
B
B
B
500
750
UNITS
VDC
Class
kV
MΩ
μA