1 2 3
NET1 SERIES
OUTPUT SPECIFICATIONS
PARAMETER
Efficiency
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
CONDITIONS/DESCRIPTION
Full Rated Load, 110 VAC. Varies with distribution of loads among outputs.
Full load, 20 MHz bandwidth.
With 300 LFM forced air cooling. (Note 1)
Output voltage overshoot/undershoot at turn-on.
Varies by output. Total regulation includes: line changes over the specified.
input range, changes in load starting at 20% load and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 10-100% load change,
1% max. deviation.
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
AdvaRnceeledasPeroduct
MIN
TYP
MAX
80
See Model Selection Charts
240
0
See Model Selection Charts
UNITS
%
Watts
%
500
µS
2
Sec
20
mS
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
Overvoltage Protection
Overload Protection
Overtemperature Protection
Output Good
Input Power Fail Warning
Current Share
Remote Sense
CONDITIONS/DESCRIPTION
MIN
TYP
MAX
Overvoltage protection on all outputs.
Unit latches off when overvoltage is detected.
AC input must be recycled to reset.
Maximum + 0.5V
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
System shutdown due to excessive internal temperature, automatic reset.
Open collector global Output Good signal. The signal activates when any of the outputs drop below 5%.
Open collector signal. Time before regulation dropout due to loss of input
5
power. May be used as independent PSOK signal in redundant applications.
Available on all outputs. Accuracy of shared current with up to 6 parallel units.
10
Single wire current share.
Available on all outputs. Total voltage compensation for cable losses with
500
respect to the main output.
UNITS
mS
%
mV
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Agency Approvals
UL1950.
CSA 22.2 NO. 234/950.
EN60950 (TÜV).
Dielectric Withstand Voltage Input to output per EN60950.
Electromagnetic Interference FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
ESD Susceptibility
Per EN61000-4-2, level 4.
Radiated Susceptibility
Per EN61000-4-3, level 3.
EFT/Burst
Per EN61000-4-4, level 3.
Input Transient Protection
Per EN61000-4-5, class 3.
Insulation Resistance
Input to output.
MIN
Line to Line
Line to Ground
2600
B
B
8
10
±2
1
2
TYP
MAX
UNITS
Approved
VDC
Class
kV
V/M
kV
kV
10
M
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
2

Share Link: 