Application Note 1456
Dynamic Load Generator
The evaluation board provides each PWM channel an
on-board dynamic load generator for evaluating the
transient-load response, which are controlled by SW1 and
SW2 respectively. The dynamic load generator applies a
300µs pulse load across VOUT and GND. The transient load
slew-rate can be trimmed by adjusting the resistors R34, R40
for the rising edge, and R38, R39 for the falling edge. +12V
power supply is needed to power the dynamic load
generator.
Connections and Test Points The following table describes the function and operation of the evaluation boards.
NUMBER
NAME
FUNCTION/OPERATION
INTERFACES AND CONNECTIONS
TP3
VBAT
VIN positive power input
TP4
GND
VIN return power input
TP1
VOUT1
Channel-1 positive power output
TP2
GND
Channel-1 return power output
TP11
VOUT2
Channel-2 positive power output
TP12
GND
Channel-2 return power output
TP20
+12V
+12V positive power input, used for the power supply of the on-board dynamic-load generator
TP19
GND
+12V return power input
TEST POINTS
J1
PHASE2
Scope-probe socket for measuring Channel-2 phase node
J3
PHASE1
Scope-probe socket for measuring Channel-1 phase node
J2
VOUT1
Scope-probe socket for measuring Channel-1 output
J5
VOUT2
Scope-probe socket for measuring Channel-2 output
J4
FLOAT_FCCM Remove the jumper will float the FCCM pin
J6
FLOAT_EN1 Remove the jumper will float the EN1 pin
J7
FLOAT_EN2 Remove the jumper will float the EN2 pin
TP17
EN1
Test point of EN1 pin
TP8
EN2
Test point of EN2 pin
TP9
LDO3EN Test point of LDO3EN pin
TP10
FCCM
Test point of FCCM pin
POWER-GOOD INDICATOR
TP13
PGOOD
Test point of PGOOD pin
D2
LED Power-Good indicator. Green when both Channel-1 and Channel-2 are in regulation.
LINEAR REGULATORS
TP14
LDO5
LDO5 linear regulator positive power output
TP15
GND
LDO5 linear regulator return power output
TP6
LDO3
LDO3 linear regulator positive power output
TP7
GND
LDO3 linear regulator return power output
SWITCHES
SW1
ON/OFF control of Channel-2 dynamic-load generator. Toggle to ON will enable the dynamic load, toggle to OFF
will disable the transient load
SW2
ON/OFF control of Channel-1 dynamic-load generator. Toggle to ON will enable the dynamic load, toggle OFF will
disable the transient load
U2
High: High level for EN1, EN2, LDO3EN and FCCM, respectively
Low: Low level for EN1, EN2, LDO3EN and FCCM, respectively
2
AN1456.0
August 25, 2009