High Speed GMSK Modem 4k to 64kbps
4
2 Signal List
MX589
Pin No.
TN/DW/P
1
2
Signal
XTAL
XTAL/CLOCK
3
ClkDivA
4
ClkDivB
5
Rx HOLD
6
RxDCacq
7
PLLacq
8
Rx PSAVE
9
VBIAS
10
Rx FB
11
Rx Signal In
12
VSS
13
DOC1
14
DOC2
15
BT
16
Tx Out
17
Tx Enable
18
Tx PSAVE
19
Tx Data
20
Rx Data
21
Rx CLK
22
Tx CLK
23
Rx S/N
24
VDD
Type
Description
output
input
input
input
input
input
input
input
input
power
output
input
input
input
output
output
output
output
power
The output of the on-chip clock oscillator.
The input to the on-chip Xtal oscillator. A Xtal, or externally derived clock (fXTAL)
pulse input should be connected here. If an externally generated clock is to be
used, it should be connected to this pin and the XTAL pin left unconnected.
Note: Operation of the MX589 without a suitable Xtal or clock input may cause
device damage.
Logic level inputs control the internal clock divider and therefore the transmit and
receive data rate. See Table 4.
Logic level inputs control the internal clock divider and therefore the transmit and
receive data rate. See Table 4.
A logic 0 applied to this input will freeze the Clock Extraction and Level
Measurement circuits unless they are in ‘Acquire’ mode.
A logic 1 applied to this input will set the RX Level Measurement circuitry to the
Acquire mode.
A logic 1 applied to this input will set the RX Clock Extraction circuitry to the
‘Acquire’ mode. See Table 5.
A logic 1 applied to this input will powersave all receive circuits except for RX
CLK output (which will continue at the set bit-rate) and cause the RX Data and
RX S/N outputs to go to a logic 0.
The internal circuitry bias line, held at VDD/2. This pin must be bypassed to VSS
by a capacitor mounted close to the pin.
Output of the RX Input Amplifier.
Input to RX input amplifier.
Negative supply (GND).
Connections to the RX Level Measurement Circuitry. A capacitor should be
connected from each pin to VSS.
Connections to the RX Level Measurement Circuitry. A capacitor should be
connected from each pin to VSS.
A logic level to select the modem BT (the ratio of the TX Filter's -3dB frequency
to the Bit-Rate). A logic 1 = BT of 0.5 and a logic 0 = BT of 0.3.
The TX signal output from the MX589 GMSK Modem.
A logic 1 applied to this input, enables the transmit data path, through the TX
Filter to the TX Out pin. A logic 0 will place the TX Out pin to VBIAS via a high
impedance.
A logic 1 applied to this input will powersave all transmit circuits except for the
TX Clock.
The logic level input for the data to be transmitted. This data should be
synchronous with TX CLK.
A logic level output carrying the received data, synchronous with RX CLK.
A logic level clock output at the received data bit-rate.
A logic level clock output at the transmit-data rate.
A logic level output which may be used as an indication of the quality of the
received signal.
Positive supply. A single 5.0V power supply is required. Levels and voltages
within this modem are dependent upon this supply. This pin should be bypassed
to VSS by a capacitor mounted close to the pin.