DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MH201 Просмотр технического описания (PDF) - WJ Communications => Triquint

Номер в каталоге
Компоненты Описание
производитель
MH201
WJ
WJ Communications => Triquint WJ
MH201 Datasheet PDF : 2 Pages
1 2
MH201
High Dynamic Range Cellular Band MMIC Mixer
The Communications Edge TM
Advanced Product Information
Product Features
Product Description
Functional Diagram
+30 dBm IIP3
RF 800 – 915 MHz
LO 550 – 715 MHz
IF 200 – 250 MHz
+17 dBm Drive Level
Low Cost SOIC-8 Package
No External Bias Required
The MH201 is a passive GaAs MESFET mixer that
provides high dynamic range performance in a low
cost SOIC-8 package. WJ’s MH201 uses patented
techniques to realize +30 dBm Input IP3 at an LO
drive level of +17 dBm when used in a simple
application circuit as an upconverting configuration.
This single monolithic integrated circuit does not
require any external baluns or bias elements.
Typical applications include frequency up/down
conversion, modulation and demodulation for
receivers and transmitters used in 2.5G and 3G
systems using the cellular frequency bands.
1
8
2
7
3
6
4
5
Function
LO
IF & RF*
GND
Pin No.
2
5
1,3,4,6,8
Specifications
Parameters1
Units
* 4 external components (inductors & capacitors)
are required to diplex the signal
Minimum Typical Maximum
Comments
Frequency Range:
RF
LO
IF
SSB Conversion Loss
Noise Figure
Input IP32
Input P1dB
Isolation:
L-R
L-I
R-I
Return Loss:
LO Port
LO Drive Level
MHz
MHz
MHz
dB
dB
dBm
dBm
dB
dB
dB
dB
dBm
800
915
550
715
200
250
9.5
10
10
+30
TBD
30
55
TBD
-5
+17
1. Data was taken using an application board shown on the following page, with a low side LO at +17 dBm in an upconverting application at 25°C.
2. Input IP3 was measured with two tones with an input power of -5 dBm / tone separated by 1 MHz.
Absolute Maximum Rating3
Application Circuit
Parameters
Rating
Operating Case Temperature
-40° to +85 °C
LO
Storage Temperature
-65° to +100 °C
Maximum Input LO Power4
+21 dBm
3. Operation of this device above any of these parameters may cause permanent damage.
4. Total sum of LO port and RF port power should not to exceed +23 dBm.
L1
27 nH
C2
5.6 pF
RF
IF
C1
12 pF
L2
15 nH
All components are of size 0402
WJ Communications, Inc Phone 1-800-WJ1-4401 FAX: 408-577-6620 e-mail: sales@wj.com Web site: www.wj.com
April 2002