ID VS. fc CHARACTERISTICS
(TYPICAL)
70
VD = 15V
60 Tj = 25°C
N-side
50
40
30
20
P-side
10
0
0
5
10 15 20 25
fc (kHz)
TRANSIENT THERMAL
IMPEDANCE CHARACTERISTICS
(BRAKE PART)
100
7
5
3
2
10–1
7
5
3
2
10–2 Single Pulse
7
5
IGBT Part;
3
2
Per unit base = Rth(j – c)Q = 0.28°C/ W
FWDi Part;
Per unit base = Rth(j – c)F = 0.44°C/ W
10–310–52 3 5 710–42 3 5 710–32 3 5 710–22 3 5 710–12 3 5 7100 2 3 5 7101
TIME (s)
MITSUBISHI <INTELLIGENT POWER MODULES>
PM200RLA060
FLAT-BASE TYPE
INSULATED PACKAGE
TRANSIENT THERMAL
IMPEDANCE CHARACTERISTICS
(INVERTER PART)
100
7
5
3
2
10–1
7
5
3
2
10–2 Single Pulse
7
5
IGBT Part;
3
2
Per unit base = Rth(j – c)Q = 0.16°C/ W
FWDi Part;
Per unit base = Rth(j – c)F = 0.25°C/ W
10–310–52 3 5 710–42 3 5 710–32 3 5 710–22 3 5 710–12 3 5 7100 2 3 5 7101
TIME (s)
May 2005