CS8191
In some cases a designer may wish to use the CS8191 only
as a driver for an air–core meter having performed the F/V
conversion elsewhere in the circuit.
Figure 11 shows how to drive the CS8191 with a DC
voltage ranging from 2.0 V to 6.0 V. This is accomplished by
forcing a voltage on the F/VOUT lead. The alternative scheme
shown in Figure 12 uses an external op amp as a buffer and
operates over an input voltage range of 0 V to 4.0 V.
100 kΩ
VREG
CS8191
CP–
–
+
10 kΩ
N/C
BIAS
VIN
2.0 V to 6.0 V DC
F/VOUT
Figure 11. Driving the CS8191 from an External
DC Voltage
Figures 11 and 12 are not temperature compensated.
100 kΩ
100 kΩ
VIN
+
0 V to 4.0 V DC
–
10 kΩ
100 kΩ
100 kΩ
CS8191
BIAS
+
–
CP–
F/VOUT
Figure 12. Driving the CS8191 from an External
DC Voltage Using an Op Amp Buffer
http://onsemi.com
10